- 13 -

GB

2.1

 ELECTRIC FRY-TOP DATA PLATE

The technical data plate is under the bottom
edge of the instrument panel.

2.2

LAWS, REGULATIONS AND TECHNICAL DIRECTIVES

The following regulations must be observed during installation:

- Current accident and fire regulations.

- The regulations of the electric power supply company.

- Health  regulations.

- Electrical systems standards.

2.3

PLACE OF INSTALLATION

- The unit should be installed in a room with adequate ventilation.

- Install the unit in compliance with the safety regulations.

2.4

POSITIONING

- The various units may be installed separately or combined with other units in the DOMINA range.

- This unit is not suitable for encasing.

- The distance from the side walls must be at least 10 cm.; should the distance be less or the material of the walls or floor be

flammable, it is vital to install heat insulation.

2.5

ELECTRICAL CONNECTION

The electrical connection must be made in compliance with CEI standards, only by authorized and skilled personnel.
Firstly, check the data given in the technical data table  of this manual, on the data plate and in the wiring diagram. The
envisaged connection is of the fixed type.

IMPORTANT

: A multi-polar mains cut-off device must be provided upstream from each oven, with a contact gap of at least

3 mm., for example:

- a manual switch of suitable capacity, equipped with fuses

- circuit breaker with relevant miniature circuit breakers.

2.5.1

EARTHING

It is vital to earth the oven.
Connect  the  terminals  marked  by  the  symbols    ( 

  )    positioned  on  the  line-in  terminal  block  to  an  efficient  grounding

complying with the regulations in force.

SPECIFIC WARNINGS
The electrical safety of this unit is assured only when it is connected correctly to an effective earthing system as stated in
the current electrical safety standards;  the manufacturer accepts no liability if these safety standards are not met.

It is necessary to verify this fundamental safety requisite and, in case of doubt, ask for the system to be tested thoroughly by
professionally  qualified  personnel.

The manufacturer cannot be deemed responsible for any damage caused by failure to earth the system.

CAUTION: NEVER CUT THE EARTH WIRE 

(yellow-green).

2.5.2

EQUIPOTENTIAL SYSTEM 

The oven must be included in an equipotential system whose efficiency must be checked according to the standards in force.
The screw marked with the ”Equipotential” label is on the back near the cable clamp.

V

KW

HZ

Matr. N°

Mod.

Summary of Contents for EFT49L

Page 1: ...IONESPARALAINSTALACI N ELUSOYELMANTENIMIENTO 15 10 2007 Rev 1 160492 FRY TOP ELETTRICO SERIE DOMINA ELECTRIC GRIDDLE PLATE SERIES DOMINA FRY TOP ELECTRIQUE SERIE DOMINA ELEKTRISCHE BRAT UND GRILLPLATT...

Page 2: ...13 2 4 Positioning 13 2 5 Electrical connection 13 2 5 1 Earthing 13 2 5 2 Equipotential system 14 2 5 3 Power supply cable 14 2 5 4 Connections to the various electric mains 14 3 Replacing the most...

Page 3: ...fficient earthing system as envisaged by the current electrical safety regulations it is therefore necessary to verify this essential requisite and in case of doubt ask professionally qualified person...

Page 4: ...If the unit is installed on its own it is advisable to secure it to make its stability safer Tab 1 L Smooth plate R Fluted plate LR 50 smooth 50 fluted plate C Chrome plate SUPPLY VOLTAGE 3NAC 415 V...

Page 5: ...ged connection is of the fixed type IMPORTANT A multi polar mains cut off device must be provided upstream from each oven with a contact gap of at least 3 mm for example a manual switch of suitable ca...

Page 6: ...mains with different characteristics to the ones envisaged or to replace the supply cable you need to remove the front panel connect the supply cable to the terminal block according to need following...

Page 7: ...ct the wires of the heating elements remove the heating element protection box remove the brackets fixing the heating element replace the part and reassemble everything following the wiring diagram Ta...

Page 8: ...oning To restore the safety thermostat take off the rubber cap and press the red push button Verify the causes of the action 4 1 USINGTHE ELECTRIC FRY TOP Turn the thermostat control knob Fig 1 Pos 1...

Page 9: ...for a few minutes in order to dry it Afterwards coat it with a light layer of Vaseline oil CHROME PLATES Clean the plate frequently with a wet rag To remove any incrustations use a strong plastic scra...

Page 10: ...ta cavo elettrico Electric cable output Sortie c ble lectrique Elektrischkabel ausgang Salida cable el ctrico SCHEMI DI INSTALLAZIONE INSTALLATION DIAGRAM SCHEMAS D INSTALLATION INSTALLATIONSPL NE ESQ...

Page 11: ...DE INSTALACI N EFTA49L EFTA99R 700 850 150 0 80 925 880 900 70 850 80 925 880 900 600 450 700 850 150 0 80 925 900 880 900 900 600 70 85 150 0 80 93 0 880 900 900 600 45 700 850 150 0 80 925 880 900 4...

Page 12: ...44 SCHEMA ELETTRICO ELECTRICAL DIAGRAM SCHEMA ELECTRIQUE SCHALTPLAN ESQUEMAS EL CTRICO EFT49 EFTA49...

Page 13: ...45 SCHEMA ELETTRICO ELECTRICAL DIAGRAM SCHEMA ELECTRIQUE SCHALTPLAN ESQUEMAS EL CTRICO EFT99 EFTA99...

Page 14: ...46...

Page 15: ...ESPA OL REGLETA RESITENCIA TERMOSTATO 50 300 BOMBILLA VERDE BOMBILLA ANARANJADO CONMUTADOR TERMOSTATO LIMITE CABLE D ALIMENTACION ABBREVIAZIONE SHORTNAME ABREVIATION KURZZEICHEN ABREVIACION N CODICE C...

Page 16: ...ientsouhaitantsed fairedecetappareil devradonccontacterlefabricantetsuivrelaproc durequecedernieraadopt eafindepermettrelacollectes par edel appareilarriv enfindevie La collecte diff renti e ad quate...

Reviews: