TM-260 273 Page 16
Handler 190
SECTION 4 − OPERATION
4-1.
Controls
1
Wire Speed Control
Use control to select a wire feed speed. As
Voltage switch setting increases, wire
speed range also increases (see weld
setting label in welding power source or
Section 4-2, as applicable).
2
Power Switch
3
Voltage Switch
The higher the selected number, the
thicker the material that can be welded
(see weld setting label in welding power
source or Section 4-2, as applicable). Do
not switch under load.
.
Switch must “click” into detent
position.
4
Gun Trigger Receptacle
5
Trigger Switch
When pressed, energized wire feeds and
shielding gas flows.