TM-260 273 Page 26
Handler 190
SECTION 7 − MAINTENANCE
7-1.
Routine Maintenance
!
Disconnect power
before maintaining.
.
Maintain more often
during severe conditions.
n
= Check
Z
= Change
~
= Clean
l
= Replace
* To be done by Factory Authorized Service Agent
Reference
Every
3
Months
l
Unreadable Labels
~
Weld Terminals
l
Damaged Gas Hose
nl
Weld Cables
nl
Cords
nl
Gun Cables
Every
6
Months
OR
~
Drive Rolls
~
Inside Unit
7-2.
Overload Protection
802 441
1
Supplementary Protector CB1
CB1 protects unit from overload. If
CB1 opens, unit shuts down.
Reset supplementary protector.
1
7-3.
Drive Motor Protection
Drive motor protection circuit protects drive motor from overload. If drive motor becomes inoperative, release gun
trigger and wait until protection circuit resets allowing drive motor to feed wire again.
Summary of Contents for H100S4-10
Page 19: ...TM 260 273 Page 17 Handler 190 4 2 Weld Parameter Chart For 230 VAC Model 248 827 B ...
Page 32: ...TM 260 273 Page 30 Handler 190 Notes ...
Page 35: ...TM 260 273 Page 33 Handler 190 248 830 A ...
Page 37: ...TM 260 273 Page 35 Handler 190 248 831 A ...