UNLOADING
1. Open the bowl guard wire cage assembly.
2. Lower bowl support.
3. Remove the agitator from the agitator shaft.
4. Slightly lift the bowl off the pin (right side), pull bowl to the front and remove from the bowl
support (left side).
WIRE CAGE
The bowl guard wire cage can be rotated out of the way to add ingredients or to access the
bowl and agitator.
Note how the plastic carriers allow the wire cage to ride around the circumference of the planetary
drip cup.
x
Open the bowl guard wire cage: rotate it to your left (Fig. 9).
x
Close the bowl guard wire cage: rotate it to your right until it stops, closed position (Fig.
10).
NOTE:
The bowl guard wire cage must be returned to the closed position for the mixer to
operate.
Fig. 9
Fig. 10
14