background image

SPECIFICATIONS 

 

Dimension: 

82 x 138 x 32mm    (3.2 x 5.4 x 1.3 inches)

 

Weight: 125 

Max test length 

Off-Line 150 meters (492.13 feet) 

 

On-Line 110 meters (360.89 feet) 

Power source 

4 x AAA    Alkaline batteries (1.5V*4) 

Working Temperature  0ºC~50ºC (32ºF ~ 122ºF) 

Storage Temperature 

-30ºC ~50ºC (-22ºF ~ 122ºF) 

Humidity 10%~90% 

 

 

 

 

 

 

 

Testing device has the following abilities: 

1.

 

Speed 1000/100/10 are supported 

2.

 

10/100/1000 Full Duplex are supported 

3.

 

10/100 Half Duplex are supported 

4.

 

12,36,45,78 all 4 pairs linked 

5.

 

Auto swap (Flash means your device has the ability to swap 

the TX and RX signals) 

6.

 

The cable length is 99 meters 

 

Testing device has the following abilities: 

1.

 

The end of the cable was not connect to any device 

2.

 

The length of Pair 1 is 99 meters     

Summary of Contents for GIGA-X

Page 1: ...GIGA X LAN Speed Link Verifier Cable Length Cable Faults Test For 10 100 1000 BASE T TX ...

Page 2: ...s network device speeds and connections status The results are then displayed on the LED An economical and versatile tool the GIGA X complies with existing CATEGORIES IEEE standards With GIGA X upgrading and installing Giga bits devices and cables in 10 100BASE T environments will be easier faster and more effective The GIGA X is also beneficial for minor changes in a 10 100 1000BASE T infrastruct...

Page 3: ...0ºC 50ºC 22ºF 122ºF Humidity 10 90 Testing device has the following abilities 1 Speed 1000 100 10 are supported 2 10 100 1000 Full Duplex are supported 3 10 100 Half Duplex are supported 4 12 36 45 78 all 4 pairs linked 5 Auto swap Flash means your device has the ability to swap the TX and RX signals 6 The cable length is 99 meters Testing device has the following abilities 1 The end of the cable ...

Page 4: ...00 Full Duplex are supported 3 10 100 Half Duplex are supported 4 12 36 2 pairs linked 5 The cable length is 22 meters Testing device has the following abilities 1 3 6 pairs linked 2 1 2 pair shorted 3 4 5 and 7 8 port shorted 4 The cable is shorted at 10 meters from tester port ...

Page 5: ...l Half duplex will light up according to the speed of the device Link Status LEDs will light up according to the pair s connected 1 2 3 6 for 10 100 device 1 2 3 6 4 5 7 8 for Giga device If cable is shorted or open 4 5 7 8 LED light up on 10 100 devices If Crossover LED is blinking this indicates that the device port is auto swappable between TR and RX z Cable is not connected to any network devi...

Page 6: ...the distributor reseller where you originally purchased the product for warranty or service 3 Misuse or unreasonable treatment of the product will void the warranty 4 LOW BAT LED will light up when the voltage is lower than 2 2V Please replace with a new alkaline battery Mixing old and new batteries is not recommended and may give inaccurate results 5 During LEDs self test if one or more LED s are...

Reviews: