10. Built-in devices
133
1.
Starting and changing the different heating levels step by step
(Off, 1 kW, 2 kW or 3 kW) with "+" or "-". The value set will
be displayed on the screen. When activated, the plus icon is
shown in green.
2.
To switch off the electric heating operation, keep pressing the
"-" key until you reach Off.
Heating with gas
To activate heating with gas:
If electricity and gas are selected together, you can set whether gas
or electricity is to take priority
(see Tools menu).
1.
Start gas operation by pressing on the liquid gas flame. The
icon for liquid gas is activated and turns green.
2.
To switch off gas operation, press the liquid gas flame. The icon
is now blue.
Hot-water floor heating system for ALDE hot-water
heating
*
If the caravan is fitted with a hot-water floor heating system, the
floor is heated by a system of pipes through which hot water flows.
In combination with heat transfer plates the heat is dispersed
throughout the entire floor of the vehicle.
Switching the hot-water floor heating system on and off
To operate the hot-water floor heating system, the hot-water he-
ating system must be switched on. This can be controlled via the
TFT control panel* or via HobbyConnect* (see also descriptions
in Chapters 7.3 and 7.3.1) as well as via the manufacturer’s own
control panel for the ALDE 3020 HE.
The hot-water floor heating system is controlled via regulating val-
ves located in the front and rear areas of the caravan (depending
on the layout plan). These valves are used to set the flow control for
the hot-water floor heating system. However, how intense the heat
is depends on the heat setting for the hot-water heating.
Maximum opening is reached by setting the valves in the direction
of the pipes. If the valves are turned by 90° to the right, they are
then closed.
To prevent heat build-up in one spot, do not place
objects for a long period of time on the hot-water floor
heating system.
Never drill holes in the floor or insert screws.
To prevent damage to the regulating valves, do not use
the space around the valves for storage.
Valves in open position
Valves in closed position