92
7. Installation of electrical
devices
7.6 Electrical system
As soon as there is a mains connection, the electrical system will switch
from battery operation to mains operation. The electrical supply unit
uses a transformer to change the external mains voltage for the 12V
electrical devices. All of the lamps in the caravan use 12V. Only large
electrical devices such as the therme, floor heating
*
, air conditioner
*
,
etc., use 230V.
CEE-Mains hook up socket
Assignment of fuses
Assignment of fuses
The fuses for the individual internal electric circuits are located in the
lighting control module. They are assigned as follows (from left to right):
In some models, there may be slight deviations in this
assignment.
Only replace blownfuses if you know what caused the
fuse to blow and have fixed this.
Electric circuit (7,5A):
children‘s bedside lights, wardrobe light (only WLU), awning light,
wall lights, ceiling light, bedside lights
Electric circuit (15A):
children‘s bedside lights
Electric circuit (7,5A):
wardrobelight, left bedside light (only WLU), ambience 2, kitchen,
shower lights
Electric circuit (7,5A):
fan, lights around the washbasin, ambience 3, ambience 1
Electric circuit (7,5A):
water pump, Toilet flush, fridge light
1
2
3
4
5
USB charging socket
* (model-specific)
The USB charging socket
j
is suitable only for charging USB-com
-
patible devices.
The 5V USB connection is supplied with power from the 12V electric
system.
USB connection
1
1
2
3
4
5
Sockets inside the vehicle
Sockets inside the vehicle
Sockets located inside the vehicle may not be used for
devices that are operated outside the vehicle.