Electrical Installations
Advice and instructions
Important
• Any changes to the electrical installations may only be car-
ried out by a professional electrician.
• Open battery circuit breaker and switch off 230V mains be-
fore carrying out maintenance work.
Batteries
• Please observe the battery manufacturer’s operating instructions.
• The acid in the battery is poisonous and corrosive. Avoid
contact with eyes and skin.
• The completely discharged battery must be recharged for at
least 10 hours. The battery may be damaged if it has been
discharged for more than 8 weeks.
• Avoid total discharge since this significantly reduces the per-
formance capacity and service life of the batteries.
• Check the level of the battery fluid regularly (acid batteries); gel
batteries require no maintenance, but must be continuously
recharged.
• Check that the clamps have been properly fitted and, if neces-
sary, remove any layers of oxide.
• Unclamp the minus pole if the ancillary battery is not being
used for a longer period of time (more than 1-2 months).Even if
the main switch of the battery has been interrupted, the batte-
ry may be recharged by the charger. (Conservation charging)
07-2
• Should the consumer battery be removed, isolate the plus
pole (to prevent short circuits when turning on the motor).
• Do not plug up the ventilation and ensure that you have ade-
quate ventilation.
Battery charger
• The charger’s capacity is 220 W.
• The charger functions in accordance with IU0U1 charging
technology.
• In the case of misuse the guarantee and manufacturer’s liability
will no longer apply.
Tank probes
• To avoid incrustations, particularly in the waste water tank,
never let the water in the tanks stand for too long. Flush the
tanks regularly.
230V main switch
• To switch off the power supply for the entire system set the
main switch to “0”(OFF).
• Only connect and disconnect the system to the 230V external
mains when the main switch is turned off.
Fuses
• Only replace defective fuses after the cause of the defect has
been remedied by a professional electrician.
• The new fuse must have the same amperage as the old one.
Summary of Contents for Van Exclusive
Page 1: ...Manual Motor home VAN VAN Exclusive Siesta Siesta Exclusive GB Version 03 2011...
Page 8: ...Introduction 01 4...
Page 48: ...Exterior Structure 05 14...
Page 82: ...Interior Structure 06 34 Day position Night position T 600 AK KM Siesta T 650 AK GFM Siesta...
Page 84: ...Interior Structure 06 36...
Page 98: ...Electrical Installations 07 14...
Page 150: ...Technical Data 13 10...