2. INSTRUCTIONS.
2.1 LED Display
Number
Description
Parameters
1
Power
Power LED
2
Battery
Battery Working Mode
Flashing while working
3
Solar
Solar Working Mode
Flashing while working
4
Battery Low
Battery Low Voltage Protection
5
Well
Led on while the water in Well is Empty
Flashing while the well sensor Low, Middle,
High Level wiring is wrong
6
Tank
Led on while the water tank is Full
Flashing while the Tank sensor Low, Middle,
High Level wiring is wrong
7
Error
Flashing and Beep Alarm Times:
1 : Input over voltage
2 : Battery low voltage
3: Battery over voltage
4: Mosfet over current
5: Foc Initial failed
6: U phase current error
7: V phase current error
8: W phase current error
9: Startup failed
10: Over temperature
11: Over current
12: Tank full of water
13: Borehole water empty
14: Potentiometer stop(controller stop )