background image

 

HOBO Pendant Event Data Logger (UA-003) Manual 

1-800-LOGGERS 2 

www.onsetcomp.com 

Specifications (continued) 

 

 

 

Plot A 

Plot B 

Connecting the Logger to a Computer 

The HOBO Pendant logger requires either of the following to 
connect to the computer: 

 

Pendant Optic USB Base Station & Coupler (BASE-U-1); 

HOBOware 2.1 or later 

OR 

 

Optic USB Base Station (BASE-U-4) or HOBO Waterproof 
Shuttle (U-DTW-1); coupler (COUPLER2A); HOBOware 2.2 or 
later 

If possible, avoid connecting at temperatures below 0°C (32°F) 
or above 50°C (122°F). 

1.  Plug the USB connector on the base station into an available 

USB port on your computer.  

2.  Insert the logger and the base station into the coupler, as 

shown in the following diagrams.  

For BASE-U-1, make sure that the logger is inserted in the 
end of the coupler that has the magnet, and that the ridges 
on the base station and logger are aligned with the grooves 
in the coupler.  

 

For BASE-U-4 or the HOBO Waterproof Shuttle, firmly insert 
the optical end of the base station into the D-shaped end of 
the coupler, and make sure that the ridge on the logger is 
aligned with the groove in the coupler.  

 

3.  If you are using the HOBO Waterproof Shuttle, briefly press 

the coupler lever to put the shuttle into base station mode.  

4.  If the logger has never been connected to the computer 

before, it may take a few seconds for the new hardware to 
be detected.  

5.  Use the logger software to set up the alarms, launch, and 

read out the logger.  

You can read out the logger or check its status while it 
continues to log, stop it manually with the software, or let it 
record data until the memory is full. Refer to the software 
user’s guide for complete details on launching, reading out, and 
viewing data from the logger. 

Important:

 Do not cover the optical communication window in 

the logger (shown in diagram above) with a label or sticker as 
that may interfere with the communications with the base 
station or shuttle.  

Connecting to a Tipping-Bucket Rain Gauge 

The logger’s black and white input wires can be connected 
directly to the relay output of most tipping-bucket rain gauges. 
(Polarity of the input connection is not important.) If your 
gauge came with a counter display and battery, disconnect 

LOGGER 

Magnet 

BASE-U-1 & COUPLER 

Ridge 

LOGGER

COUPLER2-A 

To BASE-U-4 or  
HOBO Waterproof Shuttle 

Coupler lever (for use with 
HOBO Waterproof Shuttle) 

Ridge side down 

Optical 

communication 

window 

Shop for Data Logging products online at:   

www.

DataLoggerStore

.ca   

1.800.561.8187

Summary of Contents for Pendant Event

Page 1: ...0 to 50 C 0 95 F from 32 to 122 F see Plot A A solar radiation shield is required for accurate temperature measurements in sunlight Resolution 0 14 C at 25 C 0 25 F at 77 F see Plot A Drift Less than 0 1 C year 0 2 F year Response Time Airflow of 2 m s 4 4 mph 10 minutes typical to 90 Logger Time Accuracy 1 minute per month at 25 C 77 F see Plot B Operating Range 20 to 70 C 4 to 158 F Environmenta...

Page 2: ...OBO Waterproof Shuttle briefly press the coupler lever to put the shuttle into base station mode 4 If the logger has never been connected to the computer before it may take a few seconds for the new hardware to be detected 5 Use the logger software to set up the alarms launch and read out the logger You can read out the logger or check its status while it continues to log stop it manually with the...

Page 3: ...og battery data it is recommended that you disable that channel Like other U Series loggers this logger stores internal events that are unrelated to the external event inputs Internal events are stored when the coupler is attached or detached when the battery drops below approximately 2 7V when the battery rises above 2 8V when a host computer is connected and when the logger is stopped by a comma...

Page 4: ...et and use the thumb and fingers on your other hand to slide the O ring to form a loop as shown in photo at right Use this loop to roll the O ring off the cap and over the grommet do not slide it over the circuit board 7 Inspect the O ring for cracks or cuts and replace it if any are detected the O ring is included in this logger s replacement parts kit 8 Using your fingers not cloth or paper spre...

Reviews: