If the logger does not appear in the list or if it is having 
trouble connecting, follow these tips. 

 

If the logger was configured with Bluetooth Always Off 

(see 

Configuring the Logge

r), it is currently logging at a 

fast interval (5 seconds or faster), and the temperature is 
-10°C (14°F) or below, you may need to press the button 
twice before it appears in the list. 

 

Make sure the logger is within range of your mobile 

device or computer. The range for successful wireless 
communication in air is approximately 30.5 m (100 ft) 
with full line-of-sight. 

 

Change the orientation of your device to ensure the 

antenna is pointed toward the logger. Obstacles between 
the antenna in the device and the logger may cause 
intermittent connections. 

 

If the logger is in water and configured with Bluetooth 

Off Water Detect, remove the logger from the water to 
connect to it.  

 

If your device can connect to the logger intermittently or 

loses its connection, move closer to the logger, within 
sight if possible. If the logger is in water, the connection 
can be unreliable. Remove it from water for a consistent 
connection. 

 

If the logger appears in the app, but you cannot connect 
to it, close the app and then power down your device to 
force the previous Bluetooth connection to close. 

Once the logger is connected, you can: 

Tap this: 

To do this: 

 

Specify logger settings and save them onto the 
logger to start logging. See 

Configuring the 

Logger

 

Download (offload) logger data. See 

Downloading Data From the Logger

 

Start logging if the logger was configured to start 
with a button push. See 

Configuring the Logger

 

Stop logging data (this overrides any Stop 
Logging settings described in 

Configuring the 

Logger

). 

 

Illuminate the logger LEDs for 5 seconds. 

 

Set a password for the logger that is required 
when another mobile device attempts to 
connect to it. To reset a password, press the 
button on the logger for 10 seconds or tap 
Manage Password and tap Reset. 

 

Mark the logger as a favorite. You can then filter 
the list of devices to show only loggers marked 
as favorites. 

 

Update the firmware on the logger. A logger 
readout is completed automatically at the 
beginning of the firmware update process. 

Important:

 Before updating the firmware on 

the logger, check the remaining battery level 
and make sure it is no less than 30%. Make 
sure you have the time to complete the 
entire update process, which requires that 
the logger remains connected to the device 
during the upgrade. 

 

 

Configuring the Logger 

Use the HOBOconnect app to set up the logger, including 
selecting the logging interval, start and stop logging options, 
and configuring alarms. These steps provide an overview of the 
set up features. For complete details, see the HOBOconnect 
User’s Guide. 

Note:

 Specify settings that are important to you. Press Start at 

any time to accept the defaults. 

1.

 

If the logger was previously configured with Bluetooth 
Always Off, press the button on the logger to wake it up. If 
the logger was previously configured with Bluetooth Off 
Water Detect and it is deployed in water, remove it from 
water. If you are working with multiple loggers, pressing the 
button also brings the logger to the top of the list in the 
app. 

2.

 

Tap Devices. Tap the logger tile in the app to connect to it. 

3.

 

Tap Configure & Start to configure the logger. 

4.

 

Tap Name and type a name for the logger (optional). If you 
do not enter a name, the app uses logger serial number as 
the name. 

5.

 

Tap Group to add the logger to a group (optional). Tap Save. 

6.

 

Tap Logging Interval and choose how frequently the logger 
records data unless operating in burst logging mode (see 

Burst Logging

). 

7.

 

Tap Start Logging and select when logging begins: 

 

On Save.

 Logging begins immediately after configuration 

settings are saved. 

 

On Next Interval. 

Logging begins at the next even 

interval as determined by the selected logging interval. 

 

On Button Push.

 Logging begins once you press the 

button on the logger for 3 seconds. 

 

On Date/Time.

 Logging begins at a date and time you 

specify. Select the Date and time. 

8.

 

Tap Stop Logging and specify when logging ends. 

 

Never Stop (Overwrites Old Data). 

The logger does 

not stop at any predetermined time. The logger 
continues recording data indefinitely, with newest data 
overwriting the oldest. 

 

On Date/Time.

 The logger stops logging on a specific 

date and time that you specify. 

 

After.

 Select this if you want to control how long the 

logger should continue logging once it starts. Choose 
the amount of time you want the logger to log data. 

Summary of Contents for TidbiT MX Temp 400

Page 1: ...20 to 70 C 4 to 158 F Buoyancy Fresh Water MX2203 3 1 g 0 11 oz negative MX2204 7 6 g 0 27 oz negative Waterproof MX2203 To 122 m 400 ft MX2204 To 1 524 m 5 000 ft Water Detection Water conductivity...

Page 2: ...ubstitute for the built in button see Deploying and Mounting the Logger Water Detection Screws These two screws can detect the presence of water This allows you to configure the logger in power saving...

Page 3: ...on the logger A logger readout is completed automatically at the beginning of the firmware update process Important Before updating the firmware on the logger check the remaining battery level and mak...

Page 4: ...ed value the logger alarm LED blinks and an alarm icon appears in the app Alarms alert you to problems so you can take corrective action To set an alarm 1 Tap Devices If the logger was configured with...

Page 5: ...a 10 minute logging interval and logged a data point at 9 05 Then the high limit was surpassed and burst logging began at 9 06 Burst logging then continued until 9 12 when the sensor reading fell bac...

Page 6: ...Bluetooth Always On continue to step 3 If the logger is configured with Bluetooth Always Off press the button on the logger for 1 second to wake it up If the logger is configured with Bluetooth Water...

Page 7: ...cessary Do not use harsh chemicals solvents or abrasives Periodically inspect the logger for biofouling if it is deployed in water and clean as described above Periodically inspect the O ring on the i...

Page 8: ...iew 7 While pushing down on the cover rotate it clockwise until the tab is aligned with the double ridge in the logger case If your cover has lock icons then rotate it so that the icon moves from the...

Page 9: ...ation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technici...

Reviews: