Overview:

The FN-300ULX is a power supply that converts a 115VAC / 60Hz input to a 12VDC or 24VDC regulating output 
(see specifications below).

Specifications:

- 2 -

Agency Listings:

•  UL File # S4707:

  UL Listed for Access Control 

  System Units (UL 294), UL Listed Standard for Power 

  Supplies for Use with Burglar-Alarm Systems (UL 603), 

  UL Listed Hospital Signaling and Nurse Call Equipment 

  (UL 1069), UL Listed Standard for Safety for Fire 

  Protective Signaling Systems (UL 1481).

•  MEA - NYC Department of Buildings Approved.

•  CSFM - California State Fire Marshal Approved.

Input:

•  Input 115VAC, 60Hz, 3 amp.

•  AC input and DC output LED indicators.

Output:

•  Class 2 Rated power-limited output.

•  12VDC or 24VDC selectable output. 

•  2.5 amp total supply current at 12VDC or 24VDC. 

•  Filtered and electronically regulated outputs.

•  Short circuit and thermal overload protection.

Battery Backup:

•  Built-in charger for sealed lead acid or gel type batteries.

•  Automatic switch over to stand-by battery when 

  AC fails.

•  Maximum charge current 0.7 amp.

•  Zero voltage drop when switched over to battery backup.

Supervision:

•  AC fail supervision (form “C” contacts). 

•  Low battery supervision (form “C” contacts). 

•  Battery presence supervision (form “C” contacts).

Additional Features:

•  Power supply, enclosure, cam lock and battery leads. 

Enclosures:

FN-300ULX-R (Red)

FN-300ULX-C (Charcoal Grey)

Enclosure Dimensions 

(H x W x D)

:

13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm)

Power Supply Voltage Output Selections:

Output

Switch Position

12VDC

SW1 - CLOSED (Fig. 1, on right)

24VDC

SW1 - OPEN (Fig. 1, on right)

Stand-by Specifications:

Output

4 hr. of Stand-by &

5 Minutes of Alarm

24 hr. of Stand-by &

5 Minutes of Alarm

60 hr. of Stand-by &

5 Minutes of Alarm

12VDC / 40AH Battery

Stand-by = 2.5 amp

Alarm = 2.5 amp

Stand-by = 1.0 amp

Alarm = 2.5 amp

Stand-by = 300mA

Alarm = 2.5 amp

24VDC / 12AH Battery

--------

Stand-by = 200mA

Alarm = 2.5 amp

--------

24VDC / 40AH Battery

Stand-by = 2.5 amp

Alarm = 2.5 amp

Stand-by = 1.0 amp

Alarm = 2.5 amp

Stand-by = 300mA

Alarm = 2.5 amp

Installation Instructions:

The unit should be installed in accordance with article 760 of The National Electrical Code as well as NFPA 72 and all 

applicable Local Codes.

1.  Mount unit in the desired locationMark and predrill holes in the wall to line up with the top two keyholes in the

  enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s 

  upper keyholes over the two upper screws; level and secure. Mark the position of the lower two holes. Remove the    

  enclosure. Drill the lower holes and install two fasteners. Place the enclosure’s upper keyholes over the two upper 

  screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 4).

2.  Set the FN-300ULX to the desired DC output voltage by setting SW1 (Fig. 1, pg.   2, Fig. 2c, pg. 3) to the appropriate 

  position (refer to Power Supply Voltage Output Selections chart).

3.  Connect AC power (115VAC 60Hz) to terminals marked [L, G, N] (Fig. 2, pg.   3). Use 14 AWG or larger for all 

  power connections (Battery, DC output, AC input). Use 22 AWG to 18 AWG for power-limited circuits 

  (AC Fail/Low Battery reporting).

  Keep power-limited wiring separate from non power-limited wiring (115VAC / 60Hz Input, Battery Wires). 

  Minimum 0.25” spacing must be provided.

  CAUTION: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing equipment. 

  There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel.

4.  Connect devices to be powered to terminals marked [+ DC –] (Fig. 2, pg.   3)

Altronix Corp.

140 58th St. Brooklyn, NY

OPEN SWITCH 

CLOSED SWITCH 

Switch Detail 

 

+

  DC  

--- 

 

NC    C   NO     NC   C     NO

 

 BA

T  

--- 

 

AC DC Bat

Risk of Fire,
Replace Fuses
As Marked

Opened - 24V

Closed - 12V

AC Fail

Bat Fail

J1

SW1

5A  250V

15A  250V

AC Delay

15

N

Fig. 1

Reviews: