Passenger Tire Changers Service Manual 07-13 Rev.B
13
4.2 POWER SUPPLY CABLE ON INVERTER SWITCH: CHECK AND REPLACEMENT
:
1h
: Allen keys of 6mm, 7,8,13mm tube type key, medium cross screwdriver, pliers, multimeter.
: Defective power supply cable and plug may cause the following malfunction:
1. Turning the switch on, the turntable does not turn in any direction.
2. Sometime the turntable does not turn.
3. The shut off switch of the shop shuts down.
4. Turntable Motor burning.
5. Turntable motor run with 1 or 2 phases
TO CHECK THE CABLE:
Disconnect power supply.
Remove the plug form the wall.
Remove the side panel from the machine.
Remove the foot pedal assembly from the cabinet.
Extract the foot pedal assembly from the cabinet.
Disconnect the linkage from the switch shaft and disconnect the ground wires.