12
Operation manual geodyna 2350 - 9413 126
Controls and displays
3
4
5
1
19
ALU
1
2
6
Fig.19
Display panel - central section
1
Measuring run indicators
flash alternately in top and bottom panel
- during measurement after pressing the START key
- during PRO MATCH
2
Possible
weight fitting positions
LEDs change with successive pushs of the ALU key.
3
Valve stems
- Top valve stem flashes during PRO MATCH when valve
must be positioned perpendicular to the main shaft.
- After the valve has been placed perpendicular to the
main shaft and the PRO MATCH key is pressed, the
LED is turned off.
4
SAPE symbol
- As the distance lever is moved the first bar and gradually
the remaining bar segments light up. On reaching the
correction position, the segment furthest to the right
lights up and the speaker beeps.
- The symbol lights up when the weight fitting position is
first entered and later relocated.
Note
When the wheel is rotated manually, the SAPE symbol will not
light up.
5
ALU+
lights whenever ALU+ is chosen.
6
OK
lights whenever in two-plane mode both imbalance read-
outs are 0.00.