7
Operation manual geodyna 2350 - 9413 126
Installation of the machine
·
Electrical
connection
11
12
2
1
Correct the switch point of the wheel guard switch
If the measuring run is not started (preset with C13), check the
switch point as follows:
D
Unscrew the cover from the holder of the wheel guard
arbor.
D
Undo the setscrew on the switch ring
(Fig. 11, item 1)
.
D
Adjust the switch ring so that it is contacting the
tongue of the microswitch underneath
(Fig 11, item 2)
and the measuring run is started on closing the guard
(Fig. 12)
.
D
Re-tighten the setscrew.
D
Place the cover onto the holder for the wheel guard arbor
and tighten with tapping screws.
The optional wheel guard influences the following modes
of operation:
-
The measuring run is started by closing the wheel guard
(code C13).
-
The wheel is braked on lifting the wheel guard during a
measuring run (code C5).
These modes of operation can be changed either permanently,
or only as long as the machine is switched on, by means of
codes (see § 10. Changing modes of operation).
3.
Electrical connection
In general any work on the electrical system such as fitting of
a plug or changing of connections, if necessary, must be car-
ried out by a qualified electrician in line with relevant national
standards and the regulations of the local power station.
Electrical standard equipment and drive motor of the wheel ba-
lancer are provided for operation on 50/60 Hz, 100-120 V
(-15 %, +10 %).
The connecting cable of the machine is designed as a separate
power cord. For connection to the power mains the cable is pro-
vided with a NEMA 5-15P (U.S.) or C22.2 No. 42 (Canada)
plug.
Fusing is by the customer before the plug connector, using a
15 amp circuit breaker.
The electrical diagram is illustrated in § 16.
The machine operates internally on a line voltage of 230 V be-
cause the voltage is regulated by an integrated transformer.