104
Step 2:
If a Pruefrotor is used, screw the 100g / 3.5Oz weight on the left side of the Pruefrotor. If a wheel is used
attach the 100g / 3.5Oz weight to left rim edge. If the the weight is not “100”, press and hold the “
ENTER VALUE
” key
and rotate the shaft until the custom weight is displayed.
ROTATE THE CALIBRATION TOOL / WHEEL WITH 100GR AT 12 O’CLOCK.
Press the “
ENTER
” key to enter the value of the test weight.
Step 3:
Press the “
START
” button to begin the measuring run.
Step 4:
Remove the 100 gram calibration weight and insert it into the right hand plane of the Pruefrotor / wheel.
Press the “
START
” key to begin the measuring run.
Step 5:
. Step Number 5 has not been programmed. Press the
“
ENTER
” key to advance to the procedure.