TO CHECK THE POWER ENTRY MODULE
Ø
Disconnect the power supply from the machine.
Ø
Remove the weight tray to access to the PEM.
Ø
Disconnect the wires from PEM.
Ø
Make sure that the switch is “OFF” position.
Ø
Take a multimeter and select it Ohm.
Ø
Position the multimeter terminals on Phase-Neutral, Phase-Ground and Neutral-Ground.
Ø
If the multimeter will emits a beep in one or more positions, the module is in short circuit and must be replaced.
Ø
If the multimeter will not emits any beep, the module is fi ne and the problem is caused by IBP box.
TO REPLACE THE POWER ENTRY MODULE
Ø
Turn the balancer off.
Ø
Disconnect the power supply from the machine.
Ø
Remove the cover from the IBP.
Ø
Disconnect the the cables from Power Entry Module.
Ø
Remove the screws that secure the PEM to the bracket and take it out.
Ø
Take the new module and secure it to the bracket.
Ø
Plug the new module to the main switch.
Ø
Mount the IBP box cover.
Ø
Install the panel with keypad.
Ø
Connect the machine to the power supply.
Ø
Turn the machine on and check if it works fi ne.
Ø
Turn the balancer off.
Ø
Remove the panel with keypad.
Ø
Connect the keypad and mount the weight tray.
Ø
Mount the weight tray.