92
C47
Select machine model
Options:
None
Special function:
None
Description:
Rotate the fl ange or scroll the digital slider to choice the balancer model.
Confi rm the balancer model by pressing Acknowledgment key.
Comments:
No further action is required.
C54
Checking the incremental encoder on the main shaft
Options:
Press "CONTINUE" button to switch from step to step
Special function
:
Touch screen:
Start and Stop button are displayed on the screen
Press the
Start
button to start the spin and press it
again
to stop the acceleration of the wheel.
Display of measured data/measurement statistics for the incremental encoder/code bar
So that the Optoencoder unit and the code bar can be checked, the main shaft must rotate with constant speed. As
proper performance of the Optoencoder unit is not ensured during execution of C54, speed and direction of rotation
cannot be supervised.
So after the START key is pressed to call up the function, the motor is turned on and operated under full voltage and
with the starting capacitor turned on until the ST
ART key is released. This should be done when the fi nal speed is
reached.
Once the START key is released the starting capacitor is turned off and motor voltage is reduced so that speed can be
easily maintained.
If no signal is identifi ed in one or both channels, no reading is given for the relative channel and for the phase shift.
Step
Description
min value [%]
average value [%]
max value [%]
1
A bar
min
Avg From 40 to 60
max
2
B bar
min
avg
max
3
A gap
min
Avg From 40 to 60
max
4
B gap
min
avg
max
5
A to B phase shift
min
avg
max
6
N gap channel A
biggest neighbour
N gap
[%] of average gap around [-8...+8] of reference mark
7
N gap channel A
<=108
From 160 to 220
8.1
Number of increments
Number of invalid
measurements
256 or ---
256 or ---
The values for 1-6 are read out in per-cent of the average bar/gap in the average cycle time.
Channel B is not measured
The values for 7 are read out in per-cent of the average gap width in the interval [-8 .. +8] around zero reference.
The values for 8 are counts and in case of malfunction additional error codes.
With digital machines the minimum and maximum values are read out upon operation of the Special function key, the
Option key is used to proceed to the next value.
Comments:
More detailed information about step 8 :
SM HOF GEODYNA 7600 Rel.D