33
E362
Main camera board power on self test failure
Possible causes:
•
there is a fault in the camera controller board
•
the flat cable connecting the keyboard, the
balancer controller board and the camera
controller board is partially unplugged or
damaged
•
the supply voltage is not configured properly
on the power interface board
Corrective actions:
•
check the camera controller board
•
check the connections
•
check the supply voltage with service code
C110.
E363
Left scanner self test failed, CCD not reset or zero point
mark not detected.
The balancing is not possible as the laser scanners
cannot detect the wheel data.
Problems have occurred at power-on.
•
Switch off and power-on again.
•
If the problem persists call service.
E364
Right scanner self test failed, CCD not reset or zero
point mark not detected.
The balancing is not possible as the laser scanners
cannot detect the wheel data.
Problems have occurred at power-on.
•
Switch off and power-on again.
•
If the problem persists call service.