Operator’s Manual
E365
Rear scanner self test failed, CCD not reset or zero
point mark not detected.
The laser scanners can detect the wheel data: the
balancing is possible, but the runout measurement
cannot be carried out.
Problems have occurred at power-on.
•
Switch off and power-on again.
•
If the problem persists call service.
E366
Main camera board memory self test failure
Possible causes:
•
there is a fault in the camera controller board
Corrective actions:
•
check the camera controller board.
E367
Motor power supply missing or out of range
Possible causes:
•
the cable connecting the camera controller
board and the motor power supply is
unplugged, damaged or missing
•
the motor power supply is not configured
properly
•
there is a fault in the motor power supply board
•
the cable connecting the mains supply and the
motor power supply board is unplugged,
damaged or missing
Corrective actions:
•
check all items above.
E368
Main camera board A/D converter failure
Possible causes:
•
there is a fault in the camera controller board
Corrective actions:
•
check the camera controller board.
E369
Main shaft encoder zero mark detection failure or
missing cable
Possible causes:
•
there is a fault in the camera controller board
•
there is a fault in the encoder
Summary of Contents for geodyna optima
Page 1: ...geodyna optima Additional instructions Wheel balancer ...
Page 2: ......
Page 55: ...53 geodyna optima Operator s Manual Manuel d Utilisation Note Note page La página de la nota ...
Page 56: ...54 Electrical diagram ...
Page 57: ...55 Electrical diagram ...
Page 58: ...56 Electrical diagram ...
Page 59: ...57 Electrical diagram ...
Page 61: ...Note page ...