38
Error Codes
geodyna optima
Operator’s Manual
E380
Outer CCD signals failure
Possible causes:
•
the flat cable connecting the camera controller
board and the outer scanner CCD board is
unplugged, missing or damaged
•
there is a fault in the outer scanner CCD board
•
there is a fault in the camera controller board
•
the supply voltage is configured too high on
the power interface board
Corrective actions:
•
check all items above
•
switch power off and on again; should the
problem not go away please call service.
E381
Outer scanner memory not responding
Possible causes:
•
the flat cable connecting the camera controller
board and the outer scanner CCD board is
unplugged, missing or damaged
•
there is a fault in the outer scanner CCD board
•
there is a fault in the camera controller board
Corrective actions:
•
check the connections
•
check the outer scanner CCD board
•
check the camera controller board
•
switch power off and on again; should the
problem not go away please call service.
E382
Outer scanner memory not valid
Possible causes:
•
the flat cable connecting the camera controller
board and the outer scanner CCD board is
partially unplugged or damaged
•
there is a fault in the outer scanner CCD board
Corrective actions:
•
check the connections
•
check the outer scanner CCD board
•
switch power off and on again; should the
problem not go away please call service.
Summary of Contents for geodyna optima
Page 1: ...geodyna optima Additional instructions Wheel balancer ...
Page 2: ......
Page 55: ...53 geodyna optima Operator s Manual Manuel d Utilisation Note Note page La página de la nota ...
Page 56: ...54 Electrical diagram ...
Page 57: ...55 Electrical diagram ...
Page 58: ...56 Electrical diagram ...
Page 59: ...57 Electrical diagram ...
Page 61: ...Note page ...