44
Error Codes
geodyna optima
Operator’s Manual
E400
Pull index user calibration failure
The pull index user calibration performs a scanning of
the flat surface of the calibration flange and calculates
a pull index.
This is compared with the factory/service calibration
(step 7 of C122):
•
if the difference is less then 0.5 degrees,
OK
is displayed and the user calibrated pull index
overrides the factory/service value for set of
wheels calculations;
•
if the difference is more then 0.5 degrees, the
error code
E400
is displayed and a service call
is suggested; the machine still runs using the
most recent factory/service calibrated pull
index. This might result in a slight inaccuracy
of the conicity measurement.
Corrective actions:
•
press
F6
to repeat the procedure
press
ESC
or
STOP
to release the brake and exit
the procedure.
E404
Rear shift motor current sink or power supply
failure
Possible causes:
•
the cable connecting the camera controller
board and the rear shift scanner motor is
unplugged, damaged or missing
•
the motor power supply is not configured
properly
•
there is a fault in the motor power supply board
•
the cable connecting the mains supply and the
motor power supply board is unplugged,
damaged or missing
•
there is a fault in the rear shift scanner motor
•
there is a fault in the camera controller board
motor drivers.
Corrective actions:
•
check all items above.
Summary of Contents for geodyna optima
Page 1: ...geodyna optima Additional instructions Wheel balancer ...
Page 2: ......
Page 55: ...53 geodyna optima Operator s Manual Manuel d Utilisation Note Note page La página de la nota ...
Page 56: ...54 Electrical diagram ...
Page 57: ...55 Electrical diagram ...
Page 58: ...56 Electrical diagram ...
Page 59: ...57 Electrical diagram ...
Page 61: ...Note page ...