6. Check pedal switches
E 89
Affected models
: Models with power clamp or electromagnetic brake
Service Codes
: C56 to check the pedal switches.
C75, AdC16 to check voltage to external switches
Models with solenoid brake only (e.g. 6300(p)):
One or, if available, both pedal switches are actuated. The user can now remedy the trouble. Press STOP or
ESC key to check the pedal switch once again and to delete the error code reading. If the trouble cannot be
remedied, the pedal is made inoperative.
7. Check OPTIMA Calibration
E 360
Affected models
: Models with optima hardware
Service Codes
: All codes available for the model
The optima hardware requires wheel profiler position calibration.
When the camera controller board is replaced on the machine, the SW detected that calibration data are
missing.
Calibration procedure C122 is required to calibrate the actual position of the laser scanners with respect to
the balancer reference plane,
8. Check OPTIMA Hardware
E 361
Affected models
: Models with optima hardware
Service Codes
: All codes available for the model
Wheel profiler is not present or is not responding during self test.
The balancer controller board was not able to communicate with the camera controller board during start-up
self test.
Possible causes:
•
The camera controller board is missing or dead.
•
The flat cable connecting the balancer controller board and the camera controller board is
unplugged, damaged or missing,
9. Check OPTIMA Hardware
E 362
Affected models
: Models with optima hardware
Service Codes
: All codes available for the model
Main camera board self test fail.
Balancing is not possible since wheel data cannot be scanned.
Problem during power up. Switch power off and on again. Should the problem not go away please call
service.
10. Check OPTIMA inner scanner
E 363
Affected models
: Models with optima hardware
Service Codes
: All codes available for the model
Left side scanner self test fail or CCD not calibrated or zero mark not detected.
Balancing is not possible since wheel data cannot be scanned.
Problem during power up. Switch power off and on again. Should the problem not go away please call
service.
Summary of Contents for Snap-on Y2k
Page 1: ...SERVICE of the Y2k balancing platform Seite 1 von 99 ...
Page 2: ...The vibratory assemblies of the Y2k balancing platform L R L R S S M Seite 2 von 99 ...
Page 32: ......
Page 35: ...Seite 35 von 99 ...
Page 66: ...Seite 66 von 99 Figure 1 JBEG B9000 B9450 User Interface ...
Page 67: ...Seite 67 von 99 Figure 2 JBEG B9460 User Interface ...