Seite 52 von 99
Error ID Limits
Description
18F
I2C_ERROR_NO_ACK_FROM_SEND2
190
2C_ERROR_NO_ACK_FROM_RECEIVE
191
ERROR_I2C_SYNCHRONOUS_ORDER_TIMEOUT
192
ERROR_I2C_ASYNCHRONOUS_ORDER_TIMEOUT
193
ERROR_I2C_ORDER_HAS_FAILED
201
ERROR_DS_USER_BREAK
202
Drive system : Timeout during speed up
- hand-spin only! speed does not settle after start command
203
ERROR_DS_SPEED_NOT_REACHED
204
Drive system : Speed slows down during measuring
- speed falls below limit while measuring
205
Drive system : Wheel speeds up in reverse turn
- Hand-spin only! main shaft rotating backwards on start command
206
Drive system : No acceleration during speed up or braking detected
1. Motor
2. Belt mounted?
3. Incremental encoder main shaft
207
Drive system : Slip detected (speed up to fast)
1. Wheel not clamped strong enough
2. no wheel or wheel mass to low
208
Drive system : Speed limit exceeded
- speed exceeds security limit (mainly wheel guard open and drive management set to high
speed)
210
Drive system : Clamping device got stuck in clamped position
211
Drive system : Clamping device got stuck in unclamped position
212
Drive system : Displacement limit exceeded during (un)clamping
213
Drive system : Belt disc rotates backward after clamping.
214
Drive system : Main shaft rotates during clamping (e.g. EMB defective?)
215
Drive system : Clamp device is locked
216
Drive system : Time limit for clamping process exceeded
300
Motor over-current detected by hardware.
Over-current-LED on the power interface board will be cleared on the next activation of the
motor
350
0.05 V
First Potentiometer :
Voltage below measuring range (AD value : 0..10)
351
4.45 V
First Potentiometer :
Voltage above measuring range (AD value : 1014..1024)
360
0.05 V
Second Potentiometer :
Voltage below measuring range (AD value : 0..10)
361
4.45 V
Second Potentiometer :
Voltage above measuring range (AD value : 1014..1024)
370
0.05 V
Third Potentiometer :
Voltage below measuring range (AD value : 0..10)
371
4.45 V
Third Potentiometer :
Voltage above measuring range (AD value : 1014..1024)
380
4.50 V
ASS : Voltage magnet below limit - off state.
381
1.00 V
ASS : Operating Voltage magnet below limit - on state.
382
2.00 V
ASS : Operating voltage magnet above limit - on state.
383
0.5 s
ASS : Operating Voltage magnet recharging time above limit
Summary of Contents for Snap-on Y2k
Page 1: ...SERVICE of the Y2k balancing platform Seite 1 von 99 ...
Page 2: ...The vibratory assemblies of the Y2k balancing platform L R L R S S M Seite 2 von 99 ...
Page 32: ......
Page 35: ...Seite 35 von 99 ...
Page 66: ...Seite 66 von 99 Figure 1 JBEG B9000 B9450 User Interface ...
Page 67: ...Seite 67 von 99 Figure 2 JBEG B9460 User Interface ...