Seite 53 von 99
Error ID Limits
Description
400
During measuring run : Data conditioning can't get proper speed information.
401
During measuring run : User break. (Measuring run stopped by user)
402
During measuring run : Temperature information invalid, 20°C used instead.
403
During measuring run : Can't perform transducer correction.
405
Channel 1 - channel 2 Phase shift too big
410
Transducer 1, No signal
411
Transducer 1, transimpedance to low
412
Transducer 1, RC time constant out of range
415
Transducer 1, transimpedance amplifier; idle voltage out of range
416
Transducer 1, DC amplifier; idle voltage out of range
418
Transducer 1, amplifier saturation
419
Transducer 1, Transfer function out of range
420
Transducer 2, No signal
421
Transducer 2, transimpedance to low
422
Transducer 2, RC time constant out of range
425
Transducer 2, transimpedance amplifier; idle voltage out of range
426
Transducer 2, DC amplifier; idle voltage out of range
428
Transducer 2, amplifier saturation
429
Transducer 2, Transfer function out of range
430
Transducer 1&2, No signal
431
Transducer 1&2, transimpedance to low
432
Transducer 1&2, RC time constant out of range
435
Transducer 1&2, transimpedance amplifier; idle voltage out of range
436
Transducer 1&2, DC amplifier; idle voltage out of range
438
Transducer 1&2, amplifier saturation
439
Transducer 1&2, Transfer function out of range
500
BL_BAL_ERROR_NoConverge
501
BL_BAL_ERROR_ResultInvalid
502
BL_BAL_ERROR_TooMuchLoops
510
BL_BAL_ERROR_NoCalUser
511
BL_BAL_ERROR_FailCalUser
512
BL_BAL_ERROR_SideCalUser
560
c1 value too low, if a user calibration tool assumed
561
c2 value too low, if a user calibration tool assumed
565
c1 value too low, if a 100g weight and calibration rotor assumed
566
c2 value too low, if a 100g weight and calibration rotor assumed
570
c1 value too high, if a calibration rotor only assumed
571
c2 value too high, if a calibration rotor only assumed
Summary of Contents for Snap-on Y2k
Page 1: ...SERVICE of the Y2k balancing platform Seite 1 von 99 ...
Page 2: ...The vibratory assemblies of the Y2k balancing platform L R L R S S M Seite 2 von 99 ...
Page 32: ......
Page 35: ...Seite 35 von 99 ...
Page 66: ...Seite 66 von 99 Figure 1 JBEG B9000 B9450 User Interface ...
Page 67: ...Seite 67 von 99 Figure 2 JBEG B9460 User Interface ...