Error ID Limits
Description
580
-30°C
Temperature below -30°C or hardware fault.
581
100°C
Temperature above 100°C or hardware fault.
585
0.23 V
Temperature Input near to ground Voltage.
586
4.05 V
Temperature Input near to reference Voltage.
601
Internal error : To many event sinks
602
Internal error : Cannot register event sink
603
Internal error : Invalid event level
701
ERROR_IEMS_INV_PARAM
702
Incremental encoder not initialised.
- software is not able to detect the reference mark.
703
Incremental encoder : Counter - reference mark mismatch
705
2.50 V
Opto electronic, No voltage on shunt resistor
706
4.30 V
Opto electronic, VCC on shunt resistor
707
16 mA
Opto electronic, Current through LED below limit
708
20 mA
Opto electronic, Current through LED above limit
710
Hand-spin with electromagnetic released brake
- main shaft rotates backwards
800
170 V
Line voltage below limit
801
265 V
Line voltage above limit
804
275 V
Line voltage much too high
810
5.10 V
VCC below limit
811
5.35 V
VCC above limit
820
5.00 V
Keyboard/display voltage below limit
821
5.35 V
Keyboard/display voltage above limit
830
4.50 V
External voltage (pedal) below limit, see keyboard module
831
External voltage (pedal) above limit, see keyboard module
900
Power fail detected
950
OPTIMA hardware main board fault detected
951
OPTIMA hardware inner scanner fault detected
952
OPTIMA hardware outer scanner fault detected
953
OPTIMA hardware rear scanner fault detected
9FF
ERROR_SELFTEST
e01
ASA: Status of an activated order has changed due to network manager or shop
management software activities.
Summary of Contents for Snap-on Y2k
Page 1: ...SERVICE of the Y2k balancing platform Seite 1 von 99 ...
Page 2: ...The vibratory assemblies of the Y2k balancing platform L R L R S S M Seite 2 von 99 ...
Page 32: ......
Page 35: ...Seite 35 von 99 ...
Page 66: ...Seite 66 von 99 Figure 1 JBEG B9000 B9450 User Interface ...
Page 67: ...Seite 67 von 99 Figure 2 JBEG B9460 User Interface ...