C83 Adjustment of the Unbalance Measurement (Factory Calibration)
Displayed on selection:
The digit "1" in the left display to indicate the step number.
Step 1 options:
Mount the factory calibration rotor on the balancer. Perform a measuring run.
Step 2 options:
The digit "2" in the left display to indicate the step number. "100" in the right display to indicate the mass
in grams of the calibration weight.
Press the PLUS or MINUS keys to increment or decrement the value and RETURN to select the value.
Step 3 options:
The digit "3" in the left display to indicate the step number.
Mount the calibration weight on the left side of the calibration rotor. Perform a measuring run.
Step 4 options:
The digit "4" in the left display to indicate the step number.
Remove the calibration weight and mount the calibration weight on the right side of the calibration rotor.
Perform a measuring run.
Step 5 options:
The digit "5" in the left display to indicate the step number.
Remove the calibration weight. For the motor driven machine you may leave the calibration rotor on the
shaft if you wish. For the handspin machine either the rotor shaft, or a balanced wheel is required to
provide the necessary momentum for the spin.
Perform a measuring run.
Step 6 options:
The digit "6" in the left display to indicate the step number.
Mount the "adjustment weight" on the shaft. Perform a measuring run.
After the measuring run the machine stores the new calibration values and exits to the service menu.
Pressing the PLUS and MINUS keys together at any stage will act like an Escape key and exit the code.
Summary of Contents for Snap-on Y2k
Page 1: ...SERVICE of the Y2k balancing platform Seite 1 von 99 ...
Page 2: ...The vibratory assemblies of the Y2k balancing platform L R L R S S M Seite 2 von 99 ...
Page 32: ......
Page 35: ...Seite 35 von 99 ...
Page 66: ...Seite 66 von 99 Figure 1 JBEG B9000 B9450 User Interface ...
Page 67: ...Seite 67 von 99 Figure 2 JBEG B9460 User Interface ...