117
Section 5 - Scheduled Maintenance
100 Hour Maintenance
Perform all daily maintenance along with the items
outlined in this section.
• Change crankcase lubricating oil after the first
100 hours when the pump is new and every
500 hours thereafter.
•
Service the Univalves. Refer to High Pressure
Pump Univalve Service in this manual and the
high pressure pump operation and mainte-
nance manual for instructions and additional
information.
Important:
Make sure to install the safety plug in crank
-
case drain valve when oil draining is com-
plete. The safety plug prevents crankcase
oil from draining if the valve is accidentally
opened.
200 Hour Maintenance
Perform all daily and 100 hour maintenance along
with the items outlined in this section.
•
Check and tighten all mounting bolts and
hardware.
•
Check and tighten plunger coupling bolts.
•
Inspect and lubricate the dump valve to keep
it operating properly.
•
Inspect and lubricate the manual by-pass valve
to keep it operating properly.
500 Hour Maintenance
Perform all daily, 100 and 200 hour maintenance
along with the items outlined in this section.
•
Change UHP pump crankcase lubricating oil.