119
Section 5 - Scheduled Maintenance
UHP Pump Oil Level
Crankcase Oil Level - Pump Operating:
1. Make sure the crankcase oil level is at the full
mark, then activate the charge pump and start
the engine to activate the high pressure pump.
2. Operate the pump for 3 to 5 minutes to allow
the upper sump to fill and the oil level in the
main sump to stabilize.
3. With the pump still engaged, check the oil level
in the sight gauge. The oil level should be half
way between the ADD mark and the bottom
of the sight gauge.
Crankcase Oil Level - Pump Not Operating:
1. Make sure the pump has been shutdown for
at least 5 to 8 hours or overnight.
2. Check the oil level in the sight gauge. The oil
level should be right at the FULL line.
3. If the oil level is less than half way between
the FULL and ADD marks on the sight gauge,
oil must be added to the crankcase.
Adding Oil
When oil is required, it can be added through the
breather port at the top of the crankcase or through
the back plate fill port, depending on which port is
most accessible on your unit. Always clean the area
around the fill port before removing the plug to add
oil to reduce the possibility of dirt and debris enter-
ing the crankcase when the fill plug is removed.
It is best to add oil using the back plate fill port
when possible. The oil will be added directly to
the main oil sump and the level will register im-
mediately on the sight gauge. When the breather
port at the top of sump is used, oil is added to the
upper sump and it can take several hours before
the oil will drain to the main sump and the correct
oil level will be indicated on the sight gauge.
CAUTION
THE FOLLOWING PRECAUTIONS APPLY TO AVOID DAMAGE
TO THE PUMP:
•
NEVER RUN THE PUMP WHEN THE OIL LEVEL IS NOT
VISIBLE IN THE SIGHT GAUGE.
•
DO NOT OVERFILL OIL SUMP.
•
ONLY USE A HIGH GRADE, NON DETERGENT 80W90 GEAR
OIL IN JETSTREAM PUMPS.
•
JETSTREAM PUMPS DO NOT CONSUME OIL DURING
OPERATION. A SIGNIFICANT LOSS OF OIL IS AN
INDICATION OF A LEAK SOMEWHERE IN THE PUMP
CRANKCASE. OIL LEAKS NEED TO BE REPAIRED
AS SOON AS POSSIBLE IN ORDER TO PROTECT THE
ENVIRONMENT AND THE PUMP.
Oil Level 8 Hours After
Stopping Operation
Summary of Contents for STRIPE SH7500
Page 1: ...75 H Operations Manual...
Page 2: ......
Page 72: ...72 NOTES...
Page 108: ...108 NOTES...
Page 161: ...161 Section 5 Scheduled Maintenance...
Page 167: ...167 Appendix 2 Tools Spare Parts...
Page 168: ...168 Appendix 2 Tools Spare Parts...
Page 169: ...169 Appendix 3 Daily Report Pre Op Checklist 1 877 HOG ROAD WWW STRIPEHOGSUPPORT COM 60...
Page 178: ...178 NOTES...
Page 185: ......
Page 186: ......