Section 2 - Stripe Hog Systems
illuminate to confirm the charge water pump is
engaged. The charge pressure gauge located on
the top of the control panel must be monitored
closely when engaging the charge water pump.
Once engaged, the pressure should rise immedi-
ately above 10 psi (7 BAR) and continue climbing
to the normal operating pressure of approximately
60-70 psi (4 BAR).
Water supply problems to the charge pump are
indicated by low water pressure or by the sound
of the pump. Fluctuating pump RPM, inconsistent
high pitch whines and fluctuating charge water
pressure are indications of a water supply prob-
lem to the charge pump. If the pressure does not
immediately rise and the pump is whining, im-
mediately turn the charge pump off. Make sure
the supply valve is open, check both filters and/or
bleed the air from the system. Operators should
be familiar with the normal sound of the pump
and stop blasting if the sound changes. Find and
correct the problem before waterblasting opera-
tions resume.
Charge Pump Switch In Control Panel
CAUTION
THE UHP PUMP CAN CAVITATE IF THE CHARGE WATER
PRESSURE DROPS BELOW 25 PSI (2 BAR.) CAVITATION CAN
CAUSE SEVERE DAMAGE TO THE UHP PUMP AND SHOULD
NEVER BE ALLOWED TO OCCUR. YOU SHOULD ALWAYS
MONITOR THE CHARGE WATER PRESSURE AND NEVER
OPERATE THE UHP PUMP WHEN THE CHARGE WATER
PRESSURE DROPS BELOW 30 PSI (2 BAR.)
NOTICE:
UHP SYSTEMS ARE EQUIPPED WITH A PRESSURE SAFETY
SWITCH THAT WILL DEACTIVATE THE DUMP VALVE IF
CHARGE WATER PRESSURE DROPS BELOW 30 PSI (2 BAR).
Summary of Contents for STRIPE SH7500
Page 1: ...75 H Operations Manual...
Page 2: ......
Page 72: ...72 NOTES...
Page 108: ...108 NOTES...
Page 161: ...161 Section 5 Scheduled Maintenance...
Page 167: ...167 Appendix 2 Tools Spare Parts...
Page 168: ...168 Appendix 2 Tools Spare Parts...
Page 169: ...169 Appendix 3 Daily Report Pre Op Checklist 1 877 HOG ROAD WWW STRIPEHOGSUPPORT COM 60...
Page 178: ...178 NOTES...
Page 185: ......
Page 186: ......