Error messages / continuation
Figure 37: Error message7
Cause:
a) The voltage monitoring at the load input of the
controller for the thicknessing table has tripped.
b) Fuse F3 has tripped.
c) Power unit G1 defective or overloaded.
Remedy:
Check the 24 V voltage, the fuse F3 and/or
the power supply for the thicknessing table.
Figure 38: Error message8
Cause:
The axis constantly consumes too much current.
Positioning was aborted because the maximum
axis current was exceeded.
a) The thickness table was moved against block
b) Spindle guide is too sluggish
c) Thickness table extension runs sluggishly
Remedy:
a) Release blockade
b) Clean and grease spindle guide
c) Check the table extension mechanically
Figure 39: Error message9
Cause:
Abrupt increase in current. The positioning was
stopped because the dl/t monitoring has triggered.
The thickness table was moved against block.
Remedy:
If necessary, free the workpiece from the machine and
loosen the blockage. Check the calibration values and re-
calibrate if necessary. Check the limit switches at the top
and bottom.
Further (non-control-relevant) operating faults are described in chapter