Optical Data Transmission Device for Ethernet 

EWF-0EA/B-N Specification 

C-42-04433 

6

 

Status lamp (S) led up during normal circuit operation. Also, communication is possible when both status 

lamp and CD lamp led up. 

 

Also, in this device, the light emission power is constantly monitored inside the device. In the case, when 

the light emission power is other than allowable level, the indicator lights C, L1 and L2 blinks. Stops the   

emission and will be in error mode.     

During error mode, check if the device returns to normal operation by restarting the power supply,   

If

 

error mode continues without recovery, please contact customer support. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6. Operation mode 

Slide switch which is located beside RJ connector, it can change to master mode, normal mode and slave 

Red

LAN Active lamp 

 

Green

LAN Link lamp 

 

Active

 

: Led up when transmitting/receiving data. 

Link

   

: Led up when link is established. 

Summary of Contents for EWF-0EA-N

Page 1: ...ended reason Pages Date Corrector Amended No Optical Data Transmission Device for Ethernet EWF 0EA B N Specification C 42 04433 1 9 30th Aug 2019 FA 8271 Supported network Tamaki 19th July 2019 OPTICA...

Page 2: ...hernet line between network cameras and host slave for the communication Communication distance up to 50m converts to optical wireless communication and possible to communicate between moving devices...

Page 3: ...ithout dew frost Ambient illuminance 10000lux or less Halogen mercury lamp Impact resistance 490m s2 X Y and Z directions each 10 times Vibration resistance 10 to 55Hz double amplitude of 1 5mm for 2...

Page 4: ...cuit 1 COM 2 CD 3 VIN 0V Power supply input 4 VIN DC24V Connector pin assignment for level voltage output Model No AWG No Nominal cross section Finished dimension 37104 2206 000FL AWG 20 to 22 0 3 to...

Page 5: ...Signal Signal Function 1 TD Transmission Data 2 TD Transmission Data 3 RD Reception Data 4 Not Used 5 Not Used 6 RD Reception Data 7 Not Used 8 Not Used P S L2 L1 C R Socket view View from the mattin...

Page 6: ...ht emission power is other than allowable level the indicator lights C L1 and L2 blinks Stops the emission and will be in error mode During error mode check if the device returns to normal operation b...

Page 7: ...n OFF of Slave only Slave mode Slave mode Not possible Both link does not connects Does not emits on both side Do not use other operation mode combination than above It may be the reason of data commu...

Page 8: ...eiving Disconnects LAN Link YES NO Slave mode Light receiving Disconnects LAN Link YES NO Light projecting Connected LAN link YES NO Stop emitting Slave mode Emits when light receiving and LAN link is...

Page 9: ...A to adjust so that the level output voltage of B becomes maximum Swing sidewise B to adjust so that the level output voltage of A becomes maximum If a reflector is installed on the optical axis or ne...