Document No: C-61-00003-3
Use the OSSD signal of UAM to control safety-related machines or control system. Do not use warning
signals to control safety related machine as these are non safety signals.
Both the OSSD1 and OSSD2 outputs should be connected to the safety-related machines or control
system. If OSSD3 and OSSD4 are used they must be connected in the same manner.
Use shield cable for the connection between OSSD signals and safety-related machines or systems.
Cable length should not exceed the specification.
2.5 Configuration
Configuration of safety functions are password protected. Only authorized users with password are
allowed to configure UAM.
UAM does not operate without initial configuration.
Pre-operation tests should be performed to verify the configurations before operating the UAM.
Increasing the response time of OSSD will increase the stability of UAM. However, this will reduce the
detection capability towards moving objects. User must perform risk assessment before using this
function.
Changes made during the configuration must be recorded and saved. Use the report function in the
UAM Project Designer for this purpose.
page 100
2.6 Inspection and maintenance
User must perform inspection and maintenance by referring to the checklists provided in this document
Chapter 8, page 123
・
Pre-operation inspection
・
Operation inspection
・
Daily inspection
・
Periodic inspection
The checklists in this document are provided as basic guidelines while performing the test and
maintenance. User must perform additional inspection and maintenance tasks deemed necessary for the
respective application.
Stop the machine and system if faults are detected during these tests.
Clean the optical window when it gets contaminated. If the optical window is damaged it should be
replaced by a new one.
For the repair of UAM, contact the nearest distributor or sales representative.
User should not repair or disassemble UAM.
Summary of Contents for UAM-05LP
Page 1: ... Document No C 61 00003 3 ...
Page 104: ... Document No C 61 00003 3 Figure 7 33 b Function Figure7 33 c Area ...
Page 107: ... Document No C 61 00003 3 Figure 7 36 a Project report tab Figure 7 36 b Error report tab ...
Page 148: ... Document No C 61 00003 3 13 External dimension 13 1 UAM 05LP ...
Page 149: ... Document No C 61 00003 3 13 2 Base mounting bracket ...
Page 150: ... Document No C 61 00003 3 13 3 Rear mounting bracket ...
Page 151: ... Document No C 61 00003 3 13 4 Cover Protection Bracket ...
Page 152: ... Document No C 61 00003 3 14 EC Declaration of conformity ...
Page 153: ... Document No C 61 00003 3 ...