Document No: C-61-00003-3
70
Optical interference/High
reflective background
Mount UAM at a location free
from light interference. Refer to
chapter 5.1 for light
interference counter measures.
Automatic recovery or Input
reset (During Interlock
setting)
72
Operating temperature
error
Make sure that operating
temperature is within
specification.
Restart the power supply
74-79
Power supply error
Make sure that voltage is within
the specification.
Restart the power supply
7C
OSSD excess current error
Make sure the OSSD load is
within the specification.
Restart the power supply
7D
Slave unit 1 error
Check the error code on slave
unit 1
Automatic recovery or Input
reset (During Interlock
setting)
7E
Slave unit 2 error
Check the error code on slave
unit 2
Automatic recovery or Input
reset (During Interlock
setting)
7F
Slave unit 3 error
Check the error code on slave
unit 3
Automatic recovery or Input
reset (During Interlock
setting)
80
Master unit error
Check the error code on master
unit
Automatic recovery or Input
reset (During Interlock
setting)
84,85
Object in limited detection
zone or contamination on
the optical window.
Clean the optical window (refer
to chapter 8.5 for cleaning the
optical window).
Further, remove any objects
present inside the zone with
limited detection capability
(refer to chapter 5.4) of UAM.
Automatic recovery or Input
reset (During Interlock
setting)
86
Mutual interference error
Mount UAM at a location free
from mutual interference.
Refer to chapter 5.2 mutual
interference for counter
measures.
Automatic recovery or Input
reset (During Interlock
setting)
8F
SD card detection error
Check SD card file or check the
specification of the SD card.
Automatic recovery or Input
reset (During Interlock
setting)
95-9A,
A8, AC
OSSD diagnostic error
Check the OSSD connection.
Restart the power supply
A6
EDM1 input connection
error
Check the EDM1 connection.
Restart the power supply
A7
EDM2 input connection
error
Check the EDM 2 connection.
Restart the power supply
A9
Reset input error
Check the RESET connection.
Restart the power supply
AA
Reference monitor error
Check for the displacement of
reference structure or UAM
position
Automatic recovery or Input
reset (During Interlock
setting)
Summary of Contents for UAM-05LP
Page 1: ... Document No C 61 00003 3 ...
Page 104: ... Document No C 61 00003 3 Figure 7 33 b Function Figure7 33 c Area ...
Page 107: ... Document No C 61 00003 3 Figure 7 36 a Project report tab Figure 7 36 b Error report tab ...
Page 148: ... Document No C 61 00003 3 13 External dimension 13 1 UAM 05LP ...
Page 149: ... Document No C 61 00003 3 13 2 Base mounting bracket ...
Page 150: ... Document No C 61 00003 3 13 3 Rear mounting bracket ...
Page 151: ... Document No C 61 00003 3 13 4 Cover Protection Bracket ...
Page 152: ... Document No C 61 00003 3 14 EC Declaration of conformity ...
Page 153: ... Document No C 61 00003 3 ...