Document No: C-61-00003-3
it can operate with maximum 32 sets of area. Further, it is also possible to switch the area through the speed
monitoring of incremental encoder signal connected to UAM
page 24
Table 3-1 Input combination for area switching
Mode
Protection
Max internal input
Max Area
Max encoder area
Standard
1
5
32
-
2
5
32
-
EDM
1
4
16
-
2
4
16
-
MUTING / EDM
1
2
4
-
2
1
2
-
Encoder
*
1
1
2
3
32
*2
*
1
:
Muting function and dual protection mode cannot be used if encoder input mode is selected.
*2:
Among the 4 input patters, at least one pattern must be used for encoder input. Other 3 remaining patterns
can be selected to be used as static input or not in use. A pattern with encoder input mode can have
maximum 32 sets of area (for detail, refer to section 3.6.4).