Document No: C-61-00003-3
The safety distance for this application is shown in figure 4-1.
Figure 4-4 Example Horizontal application of access protection (Dual protection zone)
4.3 Access protection (Vertical application- whole body detection)
UAM can be used as a protective shield by mounting it vertically (Figure 4-5). Application shown in the
figure is generally used in preventing the access to hazardous area. When an object or human enter the
passage, OSSD signal will switch from ON-state to OFF-state.
In this configuration, UAM detects objects or human beings in vertical plane. It is not possible to detect an
object or human being at the front or back side of the detection plane. Therefore, caution should be taken
while setting the distance between the detection plane and hazardous area. Configure the shortest response
time of UAM not exceeding 90ms. Always use reference monitoring function in such applications to detect
the displacement of fences and UAM which may expose the hazardous area. OSSD signal will switch to
OFF state when the position of reference is changed. The safety distance for this application is shown in
figure 4-6 and 4-7.
Figure 4-5 Example of access protection (Whole body detection)
Protection zone 1
Protection zone 2
Summary of Contents for UAM-05LP
Page 1: ... Document No C 61 00003 3 ...
Page 104: ... Document No C 61 00003 3 Figure 7 33 b Function Figure7 33 c Area ...
Page 107: ... Document No C 61 00003 3 Figure 7 36 a Project report tab Figure 7 36 b Error report tab ...
Page 148: ... Document No C 61 00003 3 13 External dimension 13 1 UAM 05LP ...
Page 149: ... Document No C 61 00003 3 13 2 Base mounting bracket ...
Page 150: ... Document No C 61 00003 3 13 3 Rear mounting bracket ...
Page 151: ... Document No C 61 00003 3 13 4 Cover Protection Bracket ...
Page 152: ... Document No C 61 00003 3 14 EC Declaration of conformity ...
Page 153: ... Document No C 61 00003 3 ...