No. 

S

SS

Scanning

canning

canning

canning laser range finder

 laser range finder

 laser range finder

 laser range finder

 

 

8/8 

 
9.External Design and Sensor Dimension 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Laser radiation area 

Laser radiating point 

240

°

 

Laser radiating point 

Laser radiation signal light 

CAUTION

CAUTION

CAUTION

CAUTION    

 
Use of controls, adjustments or performance of procedures other than those 
specified in this manual may result in hazardous radiation exposure. 

 

Summary of Contents for UHG-08LX

Page 1: ...er range finder laser range finder laser range finder laser range finder UHG 08LX Instruction Manual 1 8 Date 2008 1 20 MEASURING DISTANCE TYPE S S S Scanning canning canning canning laser range laser...

Page 2: ...nction please contact the nearest branch office with the following information The product name model number serial number production date Abnormal condition details including condition before and aft...

Page 3: ...m divergence is 80mm at 8m The principle of the distance measurement is based on calculation of the phase difference due to which it is possible to obtain stable measurement with minimum influence fro...

Page 4: ...Scan Angle 270 Angular Resolution 0 36 Scan Time 67msec scan Interface USB Version 2 0 FS mode 12Mbps SYNCHRONOUS OUTPUT ERROR OUTPUT Ambient Conditions Temperature Humidity 10 45 C 85 or less without...

Page 5: ...ies depending upon the operating conditions Sound level 25db or less at 300mm FDA This product complies with 21 CFR parts 1040 10 and 1040 11 5 Interface CN1 Flying lead cable 2m SIGNAL Lead Color POW...

Page 6: ...ronous output will supply one pulse scan for 10msec Figure 2 Synchronous output 2 Malfunction Output All the outputs will be turned off during malfunction Confirm the malfunction by viewing the malfun...

Page 7: ...nge is 239 765625 683 1 360 1024 Angular resolution can be specified form the host Read communication protocol specification No C 42 3320B for details Direction of motor rotation is counter clockwise...