1. Overview

The multimeter is characterized at slim size, portable, stable performance and anti-dropping capacity. 
Using  6000  counts  digit  &  bar  graph  LCD  monitor  with  character  16.5mm  high,  they  offer  clear 
readings. With overall circuitry design centering on large-scale IC A/D converters in conjunction and 
over-load protection circuit, the meters give excellent performance and exquisite making as a handy 
utility instrument. 
The meters can be used to measure DC & AC voltage, DC & AC current ( 600A range with AC/DC 
current  clamp  adapter),  resistance,  capacitor,  frequency,  duty  cycle,  temperature,  transistor  hFE, 
Non Contact AC Voltage (NCV) detection, positive diode voltage fall and audible continuity. 

2. Panel Layout

NCV detection area: Non Contact AC Voltage (NCV) detection area. 

CDS 

sensor:

 

The  CDS  sensor  can  reaction  to  the  ambient  brightness  range,  then 

automatically control the LCD backlight to lighten or go out.

 

NCV red light: Non Contact AC Voltage (NCV) detection red light. 

NCV green light: Non Contact AC Voltage (NCV) detection green light. 

LCD display: 6000 counts digit, full function symbol display.

SELECT

 key: This key work on the "

" range, press the key to choose resistance

diode

continuity or capacitance test, on the voltage or current range, change to DC or AC, on 

the 

  range, change to 

 or 

 test; If press and hold SELECT key to power on, “Auto 

Power Off ” function will be disabled. 

RANGE

 Key: Press the “

RANGE

” key, the meter enters manual range mode, press it more 

than 2 seconds again, return to auto mode.

 

REL

  Key:  Press  the  “

REL

”  key,  the  meter  enters  relative  measuring  mode,  “

REL

”  is 

displayed on the LCD and the present reading becomes the reference value and displayed on 
the display. Relative measurement R

EL

=measurement value-Reference value

. Press it again 

to exit. 

Hz/Duty

  Key:  On “ACV/ACA”  or  “Hz”  range,  press  the  “

Hz/Duty

”  key,  you  can  choose  the 

Frequency

 or 

Duty Cycle

 measurement. 

HOLD

 key: Press the “

HOLD

” key to lock display value, and the “

DH

” sign will appear on the 

display, press it again to exit. 

MAX/MIN

 key: Press the “

MAX/MIN

” key to lock 

MAX

MIN 

or

 MAX-MIN

 value, and the “

MAX

”, 

MIN

” or “

MAX-MIN

” sign will appear on the display, press it over 2 seconds to exit. 

Rotary Switch: Use this switch to select functions and ranges.

 

μA:

 μAmA, 600A current clamp adapter and Temperature “+” Input Jack 

 

20A:

 20A Input Jack 

 

VΩHz

 

:

 V/Hz/

  Input Jack 

 

COMT-:

 COM and Temperature “-” Input Jack 

Transistor hFE test Input Jack 

Crust of meter 

Protective casing 

3. Safety Information

3-1 The meter is designed according to IEC-1010 concerning electronic measuring instruments with 
an over-voltage category 1000V (CAT 

) and pollution 2. 

3-2 Follow all safety and operating instructions to ensure that the meter is used safely and is kept in 
good operating condition. 
3-3 safety symbols: 

Important safety information, refer to the operating manual. 

Dangerous voltage may be presence. 
Double insulation (protection Class II) 

4. Special Cautions for Operation

4-1 The meters can be safe only according to standard procedures when used in conjunctions with 
the supplied test leads. To replace damaged test leads with only the same model or same electric 
specifications. 
4-2 To avid risk of electric shock, do not use the meters before the cover is in place. 
4-3 The range switch should be right position for the testing. 
4-4 To avoid electric shock and damaging the instruments, the input signals are forbidden to exceed 
the specified limits. 
4-5 When measuring TV set or switched power, attention should be paid to the possible pulses that 
may bring destruction to the circuit. 
4-6 Range switch position is forbidden to be changed at random during measurement. 
4-7 Take caution against shock in the course of measuring voltage higher than DC 60V & AC 30V. 
4-8 Protection fuse should be replaced only with same type and same specification. 
4-9 After operation is finished, set function switch at OFF to save battery power. 
4-10 If the meter is without usage for long time, take out battery to avoid damage by battery leakage. 

5. GENERAL SPECIFICATIONS

5-1 Max Voltage between input terminal and Earth Ground: CAT 

1000V

.

 

5-2 Over-range Indication: display “OL” for the significant digit. 
5-3 Automatic display of negative polarity “-” . 
5-4 Low Battery Indication: “

 

” displayed. 

5-5 Max LCD display: 6000 counts digit & bar graph. 
5-6 Auto range & Manual range control 

5-7 Auto Power Off: When measurement exceeds 15 minutes without switching mode and pressing 

key, the meter will switch to standby mode. Press any key to exit standby mode. When restart 
the system, press and hold 

SELECT

 key to disable auto power off. 

5-8 Auto LCD backlight 
5-9 Fuse protection: 800mA/500V Fast Fuse, 20A/500V Fast Fuse 
5-10 Power supply: 1.5V×2 “AA” R6P battery 
5-11 Operating Temp.: 0 

 

to 40 

(relative humidity <85%) 

5-12 Storage Temp.: -10 

 

to 50 

(relative humidity <85%) 

5-13 Guaranteed precision Temp.: 23±5 

 

(relative humidity <70%) 

5-14 Dimension: 195x88x40mm 
5-15 Weight: approx. 350g (including battery) 

6. Testing Specifications

Accuracy is specified for a period of year after calibration and at 18

 

to 28

 

(64

 

to 82

with 

relative humidity to 70%. 

6-1 DC Voltage

 

Range 

Resolution 

Accuracy 

60mV 

0.01mV 

±(0.8% of rdg + 2 digits) 

600mV 

0.1mV 

±(0.5% of rdg + 2 digits) 

6V 

1mV 

60V 

10mV 

600V 

100mV 

1000V 

1V 

±(0.8% of rdg + 2 digits) 

-- Impedance: 10MΩ, More than 100MΩ on 60mV/600mV range 
-- Overload protection: 1000V DC or 750V AC rms 

6-2 AC Voltage (True RMS) 

Range 

Resolution 

Accuracy 

60mV 

0.01mV 

±(1.5% of rdg + 3 digits) 

600mV 

0.1mV 

±(1.0% of rdg + 3 digits) 

6V 

1mV 

60V 

10mV 

600V 

100mV 

750V 

1V 

±(1.5% of rdg + 3 digits) 

-- Impedance: 10MΩ, More than 100MΩ on 60mV/600mV range 
-- Overload protection: 1000V DC or 750V AC rms 
-- Frequency Range: 40 to 400Hz 

6-3 DC Current 

Range 

Resolution 

Accuracy 

600μA 

0.1μA 

±(1.2% of rdg + 2 digits) 

6000μA 

1μA 

60mA 

10μA 

600mA 

100μA 

6A 

1mA 

±(2.0% of rdg + 3 digits) 

20A 

10mA 

600A 

100mA 

±(2.5% of rdg + 5 digits) 

-- 600A range with AC/DC Current Clamp Adapter 
-- Overload protection: 800mA/500V Fast Fuse, 20A/500V Fast Fuse, 20A up to 10 seconds 

6-4 AC Current (True RMS) 

Range 

Resolution 

Accuracy 

600μA 

0.1μA 

±(1.5% of rdg + 3 digits) 

6000μA 

1μA 

60mA 

10μA 

600mA 

100μA 

6A 

1mA 

±(2.5% of rdg + 5 digits) 

20A 

10mA 

600A 

100mA 

±(3.0% of rdg + 5 digits) 

-- 600A range with AC/DC Current Clamp Adapter 
-- Overload protection: 800mA/500V Fast Fuse, 20A/500V Fast Fuse, 20A up to 10 seconds 
-- Frequency Range: 40 to 400Hz 

6-5 Resistance 

Range 

Resolution 

Accuracy 

600Ω 

0.1Ω 

±(1.0% of rdg + 3 digits) 

6kΩ 

1Ω 

±(1.0% of rdg + 2 digits) 

60kΩ 

10Ω 

600kΩ 

100Ω 

6MΩ 

1kΩ 

60MΩ 

10kΩ 

±(1.5% of rdg + 3 digits) 

-- Overload protection: 500V DC or AC rms

 

6-6 Capacitance 

Range 

  Accuracy 

Resolution 

9.999nF 

±(3.0% of rdg + 10 digits) 

1pF 

99.99nF 

±(2.5% of rdg + 5 digits) 

10pF 

999.9nF 

100pF 

9.999µF 

1nF 

99.99µF 

±(5.0% of rdg + 10 digits) 

10nF 

999.9µF 

±(10.0% of rdg + 20 digits) 

100nF 

9.999mF 

1µF 

99.99mF 

10µF 

-- Overload protection: 500V DC or AC rms

 

6-7 Frequency 

Range 

Accuracy 

Resolution 

9.999Hz 

± (0.1% of rdg + 5 digits) 

0.001Hz 

99.99Hz 

0.01Hz 

999.9Hz 

0.1Hz 

9.999kHz 

1Hz 

99.99kHz 

10Hz 

999.9kHz 

100Hz 

9.999MHz 

1kHz 

-- Sensitivity: sine wave 0.6V rms (9.999MHz: 1.5V rms) 
-- Overload protection: 500V DC or AC rms 