background image

870E 

3 1/2 DIGITAL DUAL DISPLAY 

AC CLAMP MULTIMETER 

OPERATION MANUAL 

 

1. SAFETY INFORMATION 

The  following  safety  information  must  be  observed  to  insure 

maximum personal safety during the operation at this meter. 

1.1  Do  not  operate  the  meter  if  the  body  of  meter  or  the  test  lead 

look broken. 

1.2 Check the main function dial and make sure it is at the correct 

position before each measurement. 

1.3  Do  not  perform  resistance,  temperature,  diode  and  continuity 

test on a live power system. 

1.4  Do  not  apply  voltage  between  the  test  terminals  and  test 

terminal  to  ground  that  exceed  the  maximum  limit        record  in 

this manual. 

1.5  Exercise  extreme  caution  when  measuring  live  system  with 

voltage greater than 60V DC or 30V AC. 

1.6  Keep  the  fingers  after  the  protection  ring  when  measuring 

through the test lead. 

1.7 Change the battery when the symbol appears to avoid incorrect 

data. 

2. Panel Layout

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)

 Rotary Switch: use this switch to select functions and 

ranges

 on the display. 

2)

 Back light: Push the LIGHT button to light the backlight then it 

will auto light off after approx. 5 seconds.

 

3

Data hold:    Push the HOLD button and “DH” sign will appear   

4)

 Phase lamp 

5) lack Phase LED light 

6) 

LCD Display

 

7)

 

a b c 

Input Jack 

 

3. SPECIFICATIONS 

3.1 GENERAL SPECIFICATIONS 

Display:    3 1/2 digit LCD with a max. reading of 1999. 

Polarity:    Automatic negative polarity indication. 

Zero adjustment: Automatic. 

Over range indication:    Only the "1" or "-1" display. 

    Sample rate : 2 times/sec 

Low battery indication:    “

” 

Safety  Standards:  The  meter  is  up  to  the  standards  of  IEC1010   

Double  Insulation,    Pollution Degree 2, Over voltage  Category

Clamp opening size: 45mm. 

Operating Environment: Temperature 32

104

°

F(0

40

),   

humidity

75%RH. 

Storage Environment: Temperature -4

140

°

F(-20

60

), 

humidity

90%RH. 

Power supply:    9V Zinc-carbon battery. 

Dimension:    225(H)×77(W)×45(D)mm. 

Weight: Approx.    330g (including battery). 

3.2 ELECTRICAL SPECIFICATIONS 

Accuracies are ±(% of r number in last digit) at 23

±

5

,

70%RH. 

3.2.1 DC Voltage 

Range 

Accuracy 

Resolution 

1000V 

±

(1.5% of rdg+5digits) 

1V 

Overload protection:    1000V DC/750Vrms AC   

Impedance: 10MΩ 

3.2.2 AC Voltage 

Range

 

Accuracy

 

Resolution

  Frequency 

750V 

±

(

1.8% of rdg+10digits) 

1V 

50~100Hz 

Average sensing, calibrated to rms of sine wave 

Overload protection: 1000V DC/750Vrms AC 
Impedance: 10MΩ 

3.2.3 AC Current

 

Range 

Accuracy

 

Resolution

  Frequency 

20A

 

±

(3.0% of rdg+10digits) 

10mA 

50~60Hz 

1000A 

0~800 

±

(3.5% of rdg+10digits) 

1A 

800~1000 

±

(6.5% of rdg+10digits) 

Average sensing, calibrated to rms of sine wave 

Overload protection: 1000A rms within 60 seconds 

3.2.4 Resistance 

Range

 

Accuracy

 

Resolution

 

200

Ω

 

±

(

1.0% of rdg+15digits) 

0.1 

Ω

 

2000

Ω

 

±

(

1.5% of rdg+15digits) 

Ω

 

Overload protection: 250V DC/250Vrms AC 

3

.2.5 Diode test 

Range

 

Description 

Test condition 

 

Display read 

approximately forward 

Voltage of diode. 

Forward DC current approx 

1.5mA 

.Reversed DC voltage 

approximately 3V 

Overload protection: 250V DC/250Vrms AC

 

 