HLP-NV Series
HLP-NV Series
-
103
-
Press "Auto"to active Auto mode
Connect RUN with EV to operate the drive.
Connect F/R with EV to operate the drive
10:V/F and VVC+
1: V/F
C01.01 = 0 V/F principle
C01.55 (0) (1) (2) (3) (4) (5) -- Voltage setting of V/F characteristic
10 55 380 380 380 380
C01.56 (0) (1) (2) (3) (4) (5) -- Voltage setting of V/F characteristic
0 5 50 50 50 50
2:VVC+
C01.01 = 1 VVC+ principle
C01.20 Motor Power C01.22 Motor Voltage
C01.23 Motor Frequency
C01.23 Motor Current C01.25 Motor Nominal Speed
C01.29 Automatic Motor Tuning
C01.30 Stator Resistance C01.33 Stator Leakage Ractoance
C01.35 Main Reactance
C01.60 Low Speed Load Compensation
C01.61 High Speed Load Compensation
C01.62 Slip Compensation C01.63 Slip Compensation
Use AMT to optimize motor performance in VVC+ principle
11: How to display motor speed
Example: Motor 1440/min, 50HZ
C00.31=0 , C00.32=1440
C04.14=50HZ
The custom readout will be the motor speed
12: Use LCP Pot. to realize running forward/reverse (LCP:OP-VB02)
Example: Turn the pot. clockwise from “zero” position, reference
changes from -50 to 50(reverse 50HZ—0HZ—froward50HZ)
C3.00 = 1 C3.15 = 0 C3.16 = 0 C3.17 = 21
C06.81= -50 C06.82 = 50
Press "
Auto
"to active Auto mode
Connect RUN with EV to operate the drive.
Note: In “HAND” mode, reference can only be adjusted from 0 to
maximum setting using LCP pot..
13:Use arrow keys to realize running forward/reverse in “HAND”