Wiring of the Electronic unit Type IN11-B :

The wiring diagrams are shown on page 14.

The systems power supply must be within 18Vdc to 35Vdc maximum, both main and emergency powersupply (4,35VA / 24Vdc). 
Both cables of the powersupplies must be with 2 wires and a screen.

Note : Connect the screen to the case of the electronic unit directly when it enters the housing by folding the screen back on 
the outside of the  rubber of the cable gland. 
This will prevent HF disturbances from entering the case inductivly through the power supply cables. Keep the screen 

connected on the inside of the housing so the incoming wires of the power supply can't pick up any internal signals.

Standard in/outputs of the electronic unit Type IN11-B :

- enable input for course setter / course alarm

- 20mVdc/° output signal with course alarm standard set on 10°
- potential free contact for external course alarm
- heading information output in NMEA0183 (2x)
- external dimmer input

For other options, additional interfaces are available. Please do not hesitate to ask us for information. If an option is part of the 
delivery, the relevant information and instructions will be added to these instructions.

Connecting the sensors, special attention should be paid to the following :

- all the sensors MC2/MC4/MC5 are supplied with special cable and a watertight connector at the sensor side and a separate 
  connector for connection in the electronic unit.
- this cable is very delicate and has to be installed with care
- this cable has separately shielded leads in order to prevent cross interference.
- in case you need a longer cable than delivered or additional cable for extension, you are strongly advised to use our special  
  cable. Using other types of cable might lead to non-solvable accuracy problems of the system.
- cable extensions up to 100m are possible.

Connecting the compass cable in the electronic unit IN11-B :

- remove the black outer insulation over a length of appr. 20 to 25 cm. The different colored leads with their shielding/screen 
  will become visible.
- remove these shieldings/screens from all except from one lead, cutting them off near the black outer insulation.
- make one lead of the remaining shielding/screen, by twisting them between thumb and indexfinger. If you use all the 
  shielding leads, the total lead will be to thick to handle and there may be a higher chance for short circuit caused by loose 
  strands.
-

Note : Connect the screen to the case of the electronic unit directly when it enters the housing by folding the screen back

  on the outside of the  rubber of the cable gland. 
  This will prevent HF disturbances from entering the case inductivly through the power supply cables. Keep the screen
  connected on the inside of the housing so the incoming wires of the power supply can't pick up any internal signals.

- remove the insulation from the different leads for appr. 5 mm.
- fold the strands back along the insulation and then insert them into the 
  terminal.
- do not solder the ends of these leads, because soldered leads tend to 
  break easily caused by vibrations of the ship.

The sensor MC4 is supplied  with 2m  cable and a watertight connector. 
Cable lenght from magnetic compass to the electronic unit  has to be 
ordered seperatly.
The sensor side of the connector is wired as follows and the other half must 
be wired the same (see table) :

The sensor MC2 is supplied with 10 m of cable and a watertight connector.
The sensor MC5 is supplied with 15 m of cable and a watertight connector.

9

xfiles\\tek\in11\doc\handleiding_in11b_eng.lwpp
status: definite date: 30-9-2002

pin

MC4

MC2

MC5

1

-

-

WHITE

2

*

-

-

BLACK

3

WHITE

6*

2*

4

YELLOW

YELLOW

YELLOW

5

BLUE

BLUE

BLUE

6*

RED

RED

RED

7

BLACK

BROWN

BROWN

Summary of Contents for IN11-B

Page 1: ...Manual Electronic Compass System TYPE11 B...

Page 2: ...Deviation graphic 11 Deviation table 12 Trouble shooting 13 Wiring diagram 14 Operation of the compass system 15 Compensation ranges 16 Declaration of conformity 17 Latest compensation adjustment posi...

Page 3: ...1 indication 2 aanwijzing 2 diff 2 verschil 2 remark s opmerking en 000 045 090 135 180 225 270 315 000 Tested by getest door authograph handtekening Local geomagnetic data 2 6 2003 Inclination deg 6...

Page 4: ...efered to read a magnetic compass directly When the sensor type MC5 is applied it is a stand alone compass system for see going vessels in a restricted area within 30 miles Outside this area it is per...

Page 5: ...THE CENTER OF THE BRACKET AND THE CENTER OF THE MAGNETIC COMPASS MAY NOT DIFFER MORE THAN 1 mm LARGER ERRORS THAN 1 mm WILL RESULT IN A NOT FULLY ADJUSTABLE COMPASS SYSTEM Centering the sensor place...

Page 6: ...ting brackets Mounting bracket for MC4 combination with anschutz coil Mounting bracket for MC4 combination with Robertson CD109 coil 6 xfiles tek in11 doc handleiding_in11b_eng lwpp status definite da...

Page 7: ...lines and the repeater has a nervous heading indication when the ship pitches and rolls it indicates the presence of a vertical magnetic field which has to be compensated This can only be done when th...

Page 8: ...main part of the compass system All signals compass adjustments of deviations and sensitivity of the system are processed in this unit Therefore this unit must be mounted at an easy accessable place...

Page 9: ...on solvable accuracy problems of the system cable extensions up to 100m are possible Connecting the compass cable in the electronic unit IN11 B remove the black outer insulation over a length of appr...

Page 10: ...than the scale on the sensor Then use the A potentiometer for fine adjustment Formula to calculate A correction is A dN dNE dE dSE dS dSW dW dNW 8 B adjustment With B the deviations on the E W segmen...

Page 11: ...of the ship Nervous heading indication is an indication this should be done By trail you can find a calmer heading indication which means a good adjustment of the vertical magnetic field A more nervo...

Page 12: ...de City Country Telephone Facsimile Signature Date Place 12 xfiles tek in11 doc handleiding_in11b_eng lwpp status definite date 30 9 2002 True Magnetic Heading Repeater Heading indication Deviation 00...

Page 13: ...repeater does not respond at all and the instrument illumination does not work either the cable from repeater to electronic unit must be checked as well as the mains and the fuses Make sure the volta...

Page 14: ...Wiring diagrams 14 xfiles tek in11 doc handleiding_in11b_eng lwpp status definite date 30 9 2002...

Page 15: ...ble to connect an external alarm unit The output voltage for connection to a riverpilot is 20mV The set heading can be made visable with an extra repeater which will hold the set heading and the compa...

Page 16: ...ery Local circumstances can effect some of the set parameters for switch positions and adjust possibillities see pages 20 and 21 16 xfiles tek in11 doc handleiding_in11b_eng lwpp status definite date...

Page 17: ...dress see above Country The Netherlands Standards used SOLAS 74 as amended Regulation V 12 r b IMO Resolutions A 694 17 A 813 19 IEC 60945 IEC 61162 1 ISO11606 2000E ISO11606 2001E Test report no 9501...

Page 18: ...t compensation adjustment positions Date Date Compass adjuster Compass adjuster Date Date Compass adjuster Compass adjuster 18 xfiles tek in11 doc handleiding_in11b_eng lwpp status definite date 30 9...

Page 19: ...Date Date Compass adjuster Compass adjuster Date Date Compass adjuster Compass adjuster 19 xfiles tek in11 doc handleiding_in11b_eng lwpp status definite date 30 9 2002...

Page 20: ...to the cosine circuit MC4 P12 manufacturer setting balance adjuster of the A adjuster P13 manufacturer setting adjustment maximum range B adjuster P14 manufacturer setting balance adjuster of the V a...

Page 21: ...supply manufacturer setting P5 Voltage output of the power supply manufacturer setting 12Vdc tol 0 4 P6 Balance of the power supply manufacturer setting 12Vdc 12Vdc D29 12Vdc indication D30 12Vdc indi...

Reviews:

Related manuals for IN11-B