6.4 Graph Editing
To edit a graphical table, you can do the following:
1) Drag points on the graph up or down (
Figure 18
).
2) Click twice on the numeric value to bring up the calculator (
Figure 19
).
NOTE
: the number you change may not reflect your
edit until you refresh the screen or move off the value.
Figure 18 Figure 19
7.0 Tools
The Tools section contains the following (
Figure 20
):
TPS Autoset
– Performs the TPS Autoset function. This is required on any new installation or if the TPS is changed/adjusted.
Static Timing
– Allows for a fixed timing to be entered and removed. This is used when syncing the timing. By fixing the timing to a
single value, it is much easier to check for synchronized timing all engine speeds.
Set Password
– Not currently an active feature. It does not lock out user changes via the touch screen.
Clear Password
– Not currently an active feature.
Controller Info
– Indicates ECU Firmware version (in hexadecimal format), ECU firmware version, ECU profile number, and the
software version of the Touch Screen (
Figure 21
).
Figure 20 Figure 21
Reload Last ECU Config
– Will reload the file that was last used/stored when the vehicle was last shut down.
Exit Program
– Used to exit the program.