13
Other Features
Fitting a Rain Sensor (optional)
A rain sensor can be wired directly into the terminal block. When the
sensor is wet, all automatic and manual watering will not operate.
2.
Connecting the rain sensor wires:
a)
Remove
the link connector by
loosening both screws and slide
out. (Link located under the terminal
cover.)
b) Connect the two sensor wires into
the terminal block and replace where
the link was. Fasten one wire into
the common (C), the other into the
24VAC. Polarity not applicable.
It is important to move the sensor switch back to the “ON”
position after completing your manual watering cycle.
TIP
New Sensor wires
Remove link
connector
NOTE: Far left 24VAC Terminal is active.
To fit a rain sensor follow this procedure:
1.
The sensor switch, accessed on the fascia,
must be up in the “ON” position. To over-ride the
sensor when it is wet, simply move the sensor
switch down to the “OFF” position. This will allow
automatic and manual watering cycles to operate.
DialEZY Controller 4 & 6 Station Instruction Manual Rev03.indd 13
10/06/2016 11:28 AM