IF FURTHER ASSISTANCE IS REQUIRED:
CONTACT STAR/HOLMAN FACTORY SERVICE TEAM AT 1-800-807-9054
6
#
CONVEYOR WILL NOT TURN, UNIT HEATS PROPERLY
o
DISCONNECT UNIT FROM POWER SOURCE
o
Check both fuses (replace if necessary)
o
Check for obstructions that may have caused a conveyor jam. Utensils, foil or
large pieces of food could stall the motor. If there are no visible obstructions, try
turning the belt manually. If the belt turns, remove the power supply panel and
check for loose sprockets or chain. Realign any loose sprockets and re-tighten
the setscrews making sure the setscrews seat on the flats of the motor and drive
shafts.
o
If further assistance is required, contact the
Star/Holman Factory Service
Team at 1-800-807-9054 (24 hours/day 7days a week)
.
#
COOLING FANS DO NOT START (fans should start after the machine is warmed up)
o
DISCONNECT UNIT FROM POWER SOURCE
o
Remove panels with fan motors and check fan blades for obstructions/breakage.
o
Check motor cords for secure connection
o
Call the Star/Holman Factory Service Team, as the fan switches and/or fan
motor(s) may need to be replaced.
Twin Fuse Block
Driven Sprocket
Drive Chain
Driver Sprocket
Summary of Contents for qt14