background image

 

 
 

OWNER’S MANUAL 

 
 

     

                   

 

 

 

 
 

 
 
 
 
 
 

PPU 15 Personal Power Unit

 

 

This pump complies with NFPA-1936, standard on powered rescue tool systems, 1999 edition. 

 

918.269.011 

 

 

 

 

 

 

 

 

 

 

 

 
 

Summary of Contents for PPU 15

Page 1: ...OWNER S MANUAL PPU 15 Personal Power Unit This pump complies with NFPA 1936 standard on powered rescue tool systems 1999 edition 918 269 011...

Page 2: ...ovided upon written request of the technical department of your supplier If not provided contact Holmatro directly EXCEPT AS EXPRESSLY SET FORTH ON THE ENCLOSED WARRANTY CARD HOLMATRO MAKES NO OTHER W...

Page 3: ...dealer Never disconnect the quick action couplings when the pump is in operation and when the directional valve of the pump is in either of the Operation positions 1 or 2 Use only original Holmatro a...

Page 4: ...hutoff valve E Hydraulic oil drain M Starter recoil F Fuel level indicator N Engine stop button G Fuel cap P Spark plug 3 2 Specifications Power unit model PPU 15 Allowable operating pressure 10 500 p...

Page 5: ...position Pull the cord until resistance is felt let the cord be retracted and then pull fast Repeat this if the engine does not start the first time This unit may require 10 to 12 pulls to start the e...

Page 6: ...emale coupler if it has not released completely 3 Make sure you put the dust caps back onto the couplers when not in use This is an important step to keep dirt and foreign objects from getting into th...

Page 7: ...pressure in the hydraulic hose The pressure relief device is only used to relieve pressure in hoses caused by elevated temperatures i e if the hoses are left lying in the hot sun Follow the operation...

Page 8: ...irregularly NOTE Start in the RUN position if the engine is still warm Start in the CHOKE position if the engine is cold or runs out of gasoline during operation 5 2 5 Operating The directional valve...

Page 9: ...ings and the dust caps to prevent penetration into the hydraulic system Take the dust caps apart and place them on the power unit s couplings 5 2 7 Cleaning and storage Clean the unit and any accessor...

Page 10: ...nti kink devices and prevent kinking behind the attachment 2 Prevent kinking of the hoses and never bend the hoses beyond their minimum bending radius 89 mm 3 3 Do not pull the hoses to move tools or...

Page 11: ...neutral position and connect the couplings again The quick action couplings cannot be connected Release pressure at pump by switching handle to the NEUTRAL position Reconnect the connections Check the...

Page 12: ...Remember the personal protection equipment Ensure that the pump is horizontal and never work on a pump that has not yet cooled down Work in a well ventilated area 7 3 Maintenance after the first 20 op...

Page 13: ...m the carburetor See Honda manual Replace the engine oil See procedure under maintenance after 20 hours Clean the pump and re tighten any screws that may have come loose Clean the air filter See Honda...

Page 14: ...s to and or service Holmatro rescue tools Only an active and presently authorized Holmatro dealer may disassemble the sealed parts Contact your dealer for further advice if other problems occur In the...

Page 15: ...matro by the manufacturer Damage caused by abuse improper use or corrosion Damage caused by repairs performed by persons other than a Holmatro service center or an official Holmatro factory trained di...

Page 16: ...HOLMATRO DEALER TEL FAX TOOL SERIAL NUMBER SERVICE RECORD DATE REPAIR SERVICE DESCRIPTION SERVICE TECHNICIAN Please make copies of this sheet as needed for future use...

Reviews: