IM-37-C
HOLOPHANE
HOLOPHANE
HOLOPHANE
HOLOPHANE
Arlington
®
/
Installation and
Jefferson Series
Maintenance
Manual
AFTER INSTALLATION DELIVER THIS
MANUAL TO OWNER
Arlington
Jefferson
GR163, GR1193
IMPORTANT SAFETY INSTRUCTIONS
WARNING
–
READ THESE INSTRUCTIONS
CAREFULLY BEFORE ATTEMPTING TO INSTALL OR
MAINTAIN THIS FIXTURE. WORK MUST BE DONE BY
QUALIFIED PERSONNEL.
WARNING
–
BE CERTAIN THAT ALL ELECTRICAL
POWER IS DISCONNECTED
FROM THE FIXTURE BEFORE INSTALLING
OR MAINTAINING THE FIXTURE.
WARNING
–
FOLLOW LAMP MANUFACTURER’S
OPERATING AND MAINTENANCE INSTRUCTIONS.
FAILURE TO FOLLOW THESE WARNINGS
MAY RESULT IN DEATH, INJURY OR SIGNIFICANT
PROPERTY DAMAGE.
1. INTRODUCTION
1.1 Product Description.
•
The Arlington and Jefferson products are suitable for use in wet
locations and with ambient temperatures up to 25 degree C.
•
These luminaires are designed to distribute specific patterns of
light on the surface below. All optics including glass,
polycarbonate, and acrylic have street side orientation
embossed on the flange of the refractor.
•
These luminaires are designed for easy maintenance.
•
The lamp can be accessed by disengaging the latch and raising
the top cover.
•
Electrical components are mounted on an easily removable
ballast assembly plate.
1.2 Alternate Information Sources.
Holophane
Field Service Department
P.O. Box 3004
Newark, OH 43058-3004
(866) 759-1577
2. INSTALLATION
2.1 Tools and Material Required.
Table 1. Installation Tools and Materials
DESCRIPTION
USE
1/8" Allen socket
Set screws (mounting)
1/4" nut driver or medium
Ballast assembly plate
flat screwdriver
and wire way cover
Torque wrench
Set screws
2.2 Installation of Luminaire without Photocontrol
Receptacle.
2.2.1
Disengage latch and open top cover. See Figure 1.
2.2.2
Remove refractor.
2.2.3
Loosen the two keyway screws and turn ballast plate
assembly clockwise to disengage. Rotate ballast plate assembly 90
degrees and gently lay the socket between two ribs opposite the
hinge. See Figure 2.
2.2.4
Loosen screw to wire way cover and remove wire way cover.
Feed supply leads from the pole through the wire way hole.