 Place and level the luminaire on the pole.  Position with one 

rib pointed toward the street.  Alternate tightening of the four set 
screws will assist in centering the luminaire on the post capital.  
Tighten the four set screws to 45-50 inch pounds. 

2.2.6

 

 Wire ballast and line leads accordingly.  Connect incoming 

ground wire to ground wire attached to inside of wiring chamber.  
Connect incoming common wire to wire marked COM from the 
ballast.  If a single voltage ballast is used, check the voltage number 
on the only remaining wire to verify the ballast voltage.  Connect this 
voltage wire.  Note:  Lead may require to be stripped.  If a multivolt 
ballast is used, find the correct voltage number marked on one of the 
remaining wires and make the connection.  Carefully, place 
connections in wiring chamber for future access.  See  
Figure 1. 

2.2.7

  Replace wireway cover.  Tighten screw. 

2.2.8

 

 Gently move ballast plate assembly to an upright position and 

place the assembly over the two keyway screws and turn 
counterclockwise into position.  Tighten screws. 
 
Figure 1 

 

GR206 

 

OPTICS ORIENTATION NOTES 

Some of the fixtures in this series are equipped with optical 
components that produce distributions of light that are not symmetric 
and are intended to be aimed by orienting the prismatic glass 
refractor a specific direction.  The “Street Side” marking on the top of 
the refractor should be pointed toward the street.  
 

2.2.9

 

 Replace the refractor.  Orient the refractor by locating the 

markings on the refractor flange.  Position the "street side" marking 
toward the street and align the "rib" markings with the ribs of the 
casting.  

2.2.10

  Install correct wattage and type lamp. 

2.2.11

 

 Close top cover and engage latch. 

2.2.12

 

 Energize the luminaire.  Check for proper operation. 

 

2.3  Installation of Luminaire with Photocontrol 
Receptacle. 

The photocontrol receptacle is shipped partially installed with the 
luminaire.  The receptacle will accept a standard twist-lock 
photoelectric control conforming to standards in NEMA Published 
No. SH-1959.  The receptacle is specified with a catalog number 
suffix of -R. 

Figure 2 
 

 

 

GR207 

 

Figure 3 

 

 

GR208 

 
2.3.1

  

Disengage latch and open top cover.  See Figure 1. 

2.3.2

  

Disengage electrical connector and remove wires from wire 

support.  See Figure 3. 

2.3.3

 

 Remove refractor.  Loosen the two keyway screws and turn 

ballast plate assembly clockwise to disengage.  Rotate ballast plate 
assembly 90 degrees and gently lay the socket between two ribs 
opposite the hinge.  See Figure 2. 

2.3.4

 

 Loosen screw to wire way cover and remove wire way cover.  

Feed supply leads from the pole through the wire way hole. 

2.3.5

  Place and level the luminaire on the pole.  Position with one 

rib pointed toward the street.  Alternate tightening of the four set 
screws will assist in centering the luminaire on the post capital.  
Tighten the four set screws to 45-50 inch pounds. 

Summary of Contents for Jefferson Series

Page 1: ...lycarbonate and acrylic have street side orientation embossed on the flange of the refractor These luminaires are designed for easy maintenance The lamp can be accessed by disengaging the latch and raising the top cover Electrical components are mounted on an easily removable ballast assembly plate 1 2 Alternate Information Sources Holophane Field Service Department P O Box 3004 Newark OH 43058 30...

Page 2: ...treet Side marking on the top of the refractor should be pointed toward the street 2 2 9 Replace the refractor Orient the refractor by locating the markings on the refractor flange Position the street side marking toward the street and align the rib markings with the ribs of the casting 2 2 10 Install correct wattage and type lamp 2 2 11 Close top cover and engage latch 2 2 12 Energize the luminai...

Page 3: ...fractor flange Position the street side marking toward the street and align the rib markings with the ribs of the castings 3 1 8 For photocontrol luminaire place photocontrol wires into wire support and reconnect electrical connector See Figure 3 3 1 9 Install new lamp of correct wattage and type 3 1 10 Close top cover and engage latch 3 1 11 Energize the luminaire Check for proper operation 3 2 E...

Page 4: ...b markings with the ribs of the castings 3 3 13 Place wires into wire support and reconnect electrical connector See Figure 3 3 3 14 Replace correct wattage and type lamp Close top cover and engage latch 3 3 15 Energize the luminaire Check for proper operation 4 ACCESSORIES 4 1 GV1A73 Pole Top Adaptor Refer to Figure 5 4 1 1 Place and level pole top adapter on the pole Alternate tightening of the ...

Reviews: