background image

Brightness

Increase

Brightness

reduce

 Fig 5

6

7

8

9

10

11

Sight operation

Zero setting

Maintenance and care

Limited warranty

 Fig 4

Fig 6

Protective

cap

Elevation 

adjustment knob

Windage 

adjustment 

knob

slotted 

screw

1. On top of sight is the elevation adjusting knob, windage 
     adjusting knob is on the right side (see Fig 6). The sight has 
     been  adjusted for approximate zero in factory.
2. The built in screw driver tool on the protective cap can be 
     used for zeroing adjustment (see Fig 6).  See label inside cap.
3. First open the protective cap (see Fig 6), position slot type 
    screwdriver on the slotted screw, then rotate the screw to
    right or left for adjustment. Each left or right click is for one 
    adjustment equivalent to 0.5MOA value.
4. Adjust the Elevation turret counterclockwise to move the 
     point of impact UP.  Adjust the Windage turret counter-
     clockwise to move the point of impact to the RIGHT. Turning
     either turret clockwise moves the point of impact in the 
     opposite direction. 
5. Caution: 
     Don't try to over rotate the knobs. If you feel the knobs 
     cannot be rotated, this indicates you have reached the  
     

   

     adjustment limit, otherwise the device may be damaged. If 
     the required adjusting range is beyond the limits, consider 
     adding an extra spacer between  the device and mounting 
     rail to allow for additional adjustment.

TUBE   HS406A1

Red Dot sight

        
 when powered on and off.

2. Motion sensor

     1)The motion sensor is always enabled 
     when the sight is on or in sleep mode. 
     2) If no motion is detected for 10 min, 
     the sight will save the current 
     brightness and then turn off the dot. 
     Any motion will turn on the dot to the  last saved setting.

3. Auto sleep mode

     The default sleep timer setting is 10 min, but can be adjusted

    

     1) Press and hold the “+” button for 10 seconds to enter time
          adjustment mode. There are 4 options: 10 min, 1h, 12h or
          the sleep mode is disabled.
     2) Press and release either “+” or “-” button to set the time. The LED 
          will blink (1=10 min, 2=1h, 3=12h, or 4=disable sleep mode).
    3)  Press the “+” and “-” buttons simultaneously to save the 
          time setting  and power off the sight.

4.Low battery Warning
    

If the battery voltage drops below 2.2Vdc,the dot will cycle on for 

    3 seconds and off for 0.3 seconds.
          .

     The operating panel is on the top of sight. (see  Fig 5)

1. Operation

    1) Switch on: Press and release either brightness button(”+”or”-”)
         to turn on the sight. 
    

2) Brightness adjustment: There are 12 brightness settings. The 

         default brightness is on the 7th level.  Press the "-"or "+" button
         until the red dot has a sufficient intensity to contrast against 
         the target. One quick press and release changes brightness.

    

        

   

 

   

        

3) Power off: Press  the "+" and  "-" buttons simultaneously will 

         turn the power and motion sensor off.

Note: 

The sight will remember the last saved brightness setting

         compatible rail, please contact a qualified gunsmith.

    

2) Insert included Torx wrench into 

         the clamp socket, then rotate to
         loosen the cross bolt (as shown 
         in Fig 3). Slide the sight into the 
         weapon rail to an appropriate 
         position,  and finally tighten the 
         clamp screw.

        
       This device is a precision instrument that deserves 
reasonably cautious care. The following tips are provided to 
ensure long lasting use of the sight. 

            
 

SUMMARY

    We provide a limited lifetime warranty from the date of purchase 
on parts and workmanship to the original purchaser. At our sole 
discretion, we will repair or replace product found to be defective

The optical system, including the objective lens and 
lens are multi-coated optical glass. When cleaning the lenses, 
blow away the dust on surface , wet the lens with lens cleaner or 
clean water, wiping the fingerprint or other oils with lens tissue, 
soft cotton or microfiber cloth. No special maintenance is needed 
for the housing surface. Avoid touching the glass surface with dry
cloth or tissue paper. Do not use organic solvents such as alcohol 
or acetone. Do not try to dismantle the device as the internal 
parts are specially cleaned and sealed and with an anti-fog
treatment.  Any such attempt will void the warranty.
      If repair is needed, you can call our customer service center, 
visit our website, or send an email to us.

eyepiece

under normal use and service without charge excluding any 
delivery costs, which will be born by purchaser.
    We will not be liable for incidental, consequential, or 
special damages arising out of or in any connection with the 
use or performance of this product.  This warranty is void if 
the product has been misused, modified, neglected, or 
disassembled prior to its return.        
     Please refer to http://www.holosun.com for current and 
complete warranty information.

Holosun Technologies  Inc.

www.holosun.com

Phone: 909-594-2888
Email: info@holosun.com

Customer Service

v2.1.1

Reviews: