Rev. 1.50
14�
����st ��� �01�
Rev. 1.50
143
����st ��� �01�
HT66F0175/HT66F0185
A/D Flash MCU with EEPROM
HT66F0175/HT66F0185
A/D Flash MCU with EEPROM
I
2
C Bus Start Signal
The START signal can only be generated by the master device connected to the I
2
C bus and not by
the slave device. This START signal will be detected by all devices connected to the I
2
C bus. When
detected, this indicates that the I
2
C bus is busy and therefore the HBB bit will be set. A START
condition occurs when a high to low transition on the SDA line takes place when the SCL line
remains high.
I
2
C Slave Address
The transmission of a START signal by the master will be detected by all devices on the I
2
C bus.
To determine which slave device the master wishes to communicate with, the address of the slave
device will be sent out immediately following the START signal. All slave devices, after receiving
this 7-bit address data, will compare it with their own 7-bit slave address. If the address sent out by
the master matches the internal address of the microcontroller slave device, then an internal I
2
C bus
interrupt signal will be generated. The next bit following the address, which is the 8th bit, defines
the read/write status and will be saved to the SRW bit of the SIMC1 register. The slave device will
then transmit an acknowledge bit, which is a low level, as the 9th bit. The slave device will also set
the status flag HAAS when the addresses match.
As an I
2
C bus interrupt can come from three sources, when the program enters the interrupt
subroutine, the HAAS and SIMTOF bits should be examined to see whether the interrupt source has
come from a matching slave address, the completion of a data byte transfer or the I
2
C bus time-out
occurrence. When a slave address is matched, the devices must be placed in either the transmit mode
and then write data to the SIMD register, or in the receive mode where it must implement a dummy
read from the SIMD register to release the SCL line.
I
2
C Bus Read/Write Signal
The SRW bit in the SIMC1 register defines whether the master device wishes to read data from the
I
2
C bus or write data to the I
2
C bus. The slave device should examine this bit to determine if it is to
be a transmitter or a receiver. If the SRW flag is “1” then this indicates that the master device wishes
to read data from the I
2
C bus, therefore the slave device must be setup to send data to the I
2
C bus as
a transmitter. If the SRW flag is “0” then this indicates that the master wishes to send data to the I
2
C
bus, therefore the slave device must be setup to read data from the I
2
C bus as a receiver.
I
2
C Bus Slave Address Acknowledge Signal
After the master has transmitted a calling address, any slave device on the I
2
C bus, whose
own internal address matches the calling address, must generate an acknowledge signal. The
acknowledge signal will inform the master that a slave device has accepted its calling address. If no
acknowledge signal is received by the master then a STOP signal must be transmitted by the master
to end the communication. When the HAAS flag is high, the addresses have matched and the slave
device must check the SRW flag to determine if it is to be a transmitter or a receiver. If the SRW flag
is high, the slave device should be setup to be a transmitter so the HTX bit in the SIMC1 register
should be set to “1”. If the SRW flag is low, then the microcontroller slave device should be setup as
a receiver and the HTX bit in the SIMC1 register should be set to “0”.