Holtkamp Electronics  DUO 8600XL                     techn. stand 05.2016                                            4033_05.2016 V01.2021

- 6 -

7.2  Illustration of electronic

Circuit board XL2_V021 230V~

Jp FS = 0

Jp FS = 

standard

Jumper remote start (FS):

without function

a

b

c

a

b

13 14

15

16 17

1

2

3

4

5

6 a, b ,c

7 a, b 

8

9
8

8

10

11

12

8 Installation

8.1  Installation notes

Through high quality micro-electronics is the device able to re

-

ach a high standard of reliability in the daily use. Only if the in

-

stallation has been professionally carried out can the device be 

guaranteed. 

Please consider during the installation...

 

● Only authorized and qualified electricians carry out the ins-

 

  tallation complying with the valid VDE–regulations.

 

● By the timers with 230 V~ supply voltage is definitely the 

 

  protection cable required, by the timers 24 V~ (safety ex-

 

  tra-low voltage) protecting grounding is needed as function 

 

 earth.

 

● That the floor covering is anti-static and conductor capable, 

 

  to ensure a minimum of static change and so reducing 

 

  the danger to the electronics.

 

● A malfunction or breakdown of the device can be caused 

 

  by the switching sparks of the relay contacts. To reduce 

 

  these  sparks appropriate suppression combinations must 

 

  be included parallel to the protection contacts. RC combi-

 

  nations for sparks reducing are only affective by direct par-

 

  allel switching of the relay contacts.

 

● That the screened control and data cable are laid separa-

 

  tely from mains cables. The screening of the DUO electro-

 

  nic must be one - side and laid on PE.

 

● That the feed line are used, which is from a big cross section 

 

  to supply both the DUO and the attached electric consumer. 

 

  It should be used an cross section from 1,5 mm² at the mi-

 

  nimum.

1  Serial interface 

2  Connection for multiple coin  

 

 tester 

3  Battery 

4  Connection for serial remote 

 

 

display 

5  Connection for bridge switch 

6a  Additional relay for 110%-dis

 

 connection 

6b   Main relay 

6c   Run-out relay   

7a   Fuse main relay 

7b   Fuse lead relay 

8  Power connection 

9  Potential free relay connection 

10   PCB fuse 

11   Connection for foil keyboard 

12   Connection for chip card contact  

 unit 

13   Connection for chip card reject 

14   Connection for external timer 

15   DIP switch no. 1 – 4

16   Connection for remote start 

17   Connection for time hold/

 

 

cleaning button 

 

 

Special equipment

Summary of Contents for DUO 8600 XL

Page 1: ...Operating instruction DUO 8600 XL Coin and chip card system ...

Page 2: ...se Erklärung gilt für alle Geräte die nach den beiliegenden technischen Unterlagen welche Bestandteile dieser Erklärung sind hergestellt werden This explanation applies to all devices after the enclosed technical documents which are components of this explanation are manufactured Einschlägige EG Richtlinien Relevant EC guidelines RoHS Richtlinie 2011 65 EU RoHS Directive 2011 65 EU 1 2006 95 EG Ni...

Page 3: ... Statistics 23 14 1 Explaining the statistics values 23 14 2 Enquiring the statistic values in operation mode Timer 24 14 3 Enquiring the counter readings in operating mode Revaluation 24 14 4 Cancelling the statistic values 25 14 5 Enquiring the failure statistics 25 14 6 Readout the code 26 14 7 Cancelling the failure statistics 26 15 Not programmable special equipments 26 15 1 Electric contacto...

Page 4: ... ZVEI also see website www holtkamp de Any liability extinguished by the manipulation of the device 3 Safety notices The coin chip card boxes are built according to the prior art and the recognized safety rules Nevertheless its use threats to life and limb of the user or third parties or cause damage to the device or other equipment du ring use Use the device only in perfect condition and in tende...

Page 5: ...coin bag app 15 kg Fuse circuit board SI 1 100mA T Fuse main relay SI 2 6 3A MT Fuse run out relay SI 3 6 3A MT Attention Fuses may only be replaced with the same value We reserve the right to technical changes in the production and technical developments 7 Illustrations 7 1 Illustration of the devices 1 2 3 4 5 6 7 8 9 10 11 12 13 14 18 15 16 14 18 17 14 15 19 20 21 1 Casing 2 Card slot 3 Coin sl...

Page 6: ...n or breakdown of the device can be caused by the switching sparks of the relay contacts To reduce these sparksappropriatesuppressioncombinationsmust be included parallel to the protection contacts RC combi nations for sparks reducing are only affective by direct par allel switching of the relay contacts That the screened control and data cable are laid separa tely from mains cables The screening ...

Page 7: ...ise the casing so that it is possible to pull out theelectricalconnectors Pullouttheelectricalplugconnec tions and remove the casing completely The wall plate horizontal and vertically align with the help of a level The tilt angle can only be 2 now mark the drilled holes Drilltheholesandinsertsuitabledowels Throughtheholes 15 see image 1 1 of the device on the rear wall connect up the electricity ...

Page 8: ...e the main time too long because of the danger of the sun bed customer Use the adjustment setting to limit the maximum time and therefore limiting the maximum account of buyable main time to reduce to a minimum the danger to the customer 8 5 1 LED operating light With the LED operating light one can see at a glance the opera ting stand of the DUO During the lead time quick blinking main time perma...

Page 9: ... cards see chip card brochure included in the standard version Special equipment by choice or included in the standard version available in Holtkamp design on request with customer specific design foil available 10 Chip card types There are various chip card types to distribute to customers as a means of payment and to program the standard and special functions Chipkarte Typ PIN Card Funktion P11 ...

Page 10: ...arted by putting in a revaluation card type 73 The revaluation process functions in the same way as the timer operation The program ming and statistic menus are adapted on this operating mode Redundant points are omitted and needed points are added 12 General at programming The individual program positions can be accessed in quick pass auto repeat function forward and backward As following needs t...

Page 11: ...the remote start and the main time starts immediately In the second case the lead time is set on 0 In this case begins the main time first after activating the remote start This can be called as a forced remote start Should a connected customer be operated without delay and activating the remote start the jumper FS must be activated on 0 see picture of electronic chap 1 2 The remote start has to b...

Page 12: ... be bought by choice If you pay with chip card the maximum time you can pay is limited by the skin type or by the first tanning which is deposit on the chip card The maximum time is adjusted on the absolutely highest minute time amount of all skin types limit switching It should be adjusted the minute value at most which conforms of a dose of 800 J m this is to infer from the manual of the tanning...

Page 13: ...ill be valued additional to the containing debit the bonus value will be credited on the card Bonus Step 2 0 0 EUR With the bonus step 2 is set a cash amount This amount must be bigger than the one in bonus step1 Should with the card type 11 inserted this amount be inserted then additional to the inserted cash the value under the set bonus amount will be credited on the card Immediately a bonus am...

Page 14: ...t main time has been bought inserting more coins permits the further buying of the next period By activating minimum insert can be used the function price step card If yes is set is the minimum insert activated If no is set is the minimum insert deactivated HQL time yes The HQL Time offers the possibility to hinder the new start of a main time during the run out time The newly bought main time wil...

Page 15: ...l be scrolled Autom Summertime yes Automatic summer time switching is to be set up on yes or no yes in the last Sunday of March the time is set automatic on summer time in last Sunday of October it will be automatic set on wintertime The changing timings will be calculated and do not have to be set At the beginning of the summer time the clock will be set up with 1 hour forward at night from 2 00 ...

Page 16: ...f is freely chosen between ta riff 1 2 3 and blockage A payment is not possible during the activated blocka ge Switch time Mo Fr 4 Fourth switching time valid from Monday to Friday Tariff Mo Fr 4 Fourth tariff valid from Monday to Friday The tariff is freely chosen between tariff 1 2 3 and blockage A payment is not possible during the activated blockage Switch time Sa 1 First switching time valid ...

Page 17: ...nged Coin tester value chan 1 The coin tester revaluation Channel 1 offers the possibility to set the channel value for channel 1 The valuing can be set in 0 1 steps from 0 0 25 5 With the RESET and PLUS button you can change the values with the OK button you can switch over to the next menu point By setting from 0 0 the coin tester will accept the coins but there will be no time buying If the coi...

Page 18: ... the thrown in coins you can also see on the label on the cover from the coin tester It is possible to blocked several coins Thereby the coin accep tation is refused 9 10 11 12 13 14 15 16 2 0 EURO wide yes 2 0 EURO middle yes 0 5 EURO wide yes 0 5 EURO narrow yes 1 0 EURO narrow yes Teach function no EURO yes 2 0 EURO narrow yes 1 2 3 4 5 6 7 8 Token standard no 0 2 EURO wide no 0 2 EURO middle n...

Page 19: ... for one hour at night from 2 00 to 3 00 at the end of summer time it will be reset by one hour at night from 3 00 to 2 00 These switchover dates corres pond to the summer time arrangements agreed in the European Union They were also taken over by many other states no no automatic summer time switching Notes for the electronic multi coin acceptor Your DUO is equipped with an electronic multiple co...

Page 20: ...s the possibility to obviate the repeated sale of main time If yes is set the main time can be bought only once If no is set can the main time repeatable sold Mains failure fuse no The mains failure fuse offer the possibility that the main time remains even after a mains failure After the mains supply is restored again the devices with the stored main time will be switched back on per random time ...

Page 21: ...t have a different device no There may not be distributed double because the bus system can t read the particular address Besides the no of the SkinControl device must correspond with the no of the particular tanning beds Card verify no This setting must generally be on no If yes is adjusted no contact to the central Test mode no On setting the Testing you have the possibility with the setting no ...

Page 22: ...re registered as service actions should not be registered Please take note that the devalue actions also the cancelling of the chip card will be registered and therefore a negative value could be shown on these re value counters Pre conditions to revalue are that the DIP switch Number 3 is on delivery stand and the menu item Revalue step card in the price time menu is set to a value except null To...

Page 23: ...3 set on on Total EMP revalue impulse counter Counts the bonus amounts given when re valued with in serted coins does not count chip cards type 14 and 15 Total EMP bonus impulse counter Counts when re valued with inserted coins without bonus does not count chip cards type 14 and 15 Total customer impulse counter As daily costumer counter can only be cancelled with the chip card type 43 and the DIP...

Page 24: ...ev IC 100 0 EUR Total EMP bon IC 100 0 EUR 2 x possible The grey deposited menu options must only in the configuration menu with the menu options Daily counter yes or money token impulse counters yes EMP revalue yes to be activated or in the program ming menu Revaluation step 0 otherwise it do not appear by the pro gramming IC impulse counter 14 3 Enquiring the counter readings in operating mode R...

Page 25: ...ts is not possible daily counter only or pull out chip card type 43 Pull out chip card type 33 or 14 5 Enquiring the failure statistics When you are in the normal mode you can change to the stati stic menu by hold pressed PLUS button and insert chip card type 43 Unhand the PLUS button With OK button you can change to the next menu point You quit the menu with extraction the chip card to call with ...

Page 26: ...connected device If the power input is under 40 80 or 100 mA as ordered the main time count down will be interrupted 15 4 Extra connection for cleaning button The extra connection for the cleaning button offers the possibility to disable the connected device after every use until an external button has been pressed The disabled condition is shown by the word cleaning blinking in the display If you...

Page 27: ...t but ton If your DUO has been ordered with a remote start button you can find on the SB frame on the inside of the back of the device an additional circuit board which needs to be connected to the remote indication as following The needed connection cable is not included by delivery Connection to the XL with 4 pol installation cable shielded screen on one side presented maximum conduit length 12 ...

Page 28: ...electronic multiple coin tester takes on sporadic coins only coin tester is dirty bad quality of coins Verschmutzung beseitigen andere Mün ze verwenden chosen a narrow adjustment Einstellung am DIP Schalter des EMP ändern siehe auch Münzprüferwertig keiten the electronic multiple coin acceptor is defectively send the electronic multiple coin accep tor to repair The coin remains hanging in the coin...

Page 29: ...ust be smaller or even with the 3 service interval The display shows error message E32 By bonus operation No discount could be assigned because programming contra dicts the bonus system The programmed prices and main times must be so adjusted that with reaching a bonus step no negative bonus is assi gned the customer lost time instead get more The display shows error message E33 or E27 By bonus op...

Page 30: ...ontactor 26 Electronic illustration 6 EMP daily bonus impulse counter 23 EMP daily revalue impulse counter 23 EMP revaluation 20 Enquiring the counter readings in operating mode Revaluation 24 Enquiring the failure statistics 25 Enquiring the statistic values in operation mode Timer 24 Explanation of the program positions 10 Extra connection for cleaning button 26 Extra connection for time stop 26...

Page 31: ... Specifications 9 Statistics 23 Statistics values 23 Switch time 16 T Tariff 16 Test mode 21 Time price menu 11 Timer operating 10 Time stop 26 Token counter 19 Token daily pulse counter 6 23 Token impulse counter 20 Total card impulse counter 23 Total cash impulse counter 23 Total customer impulse counter 23 Total EMP bonus impulse counter 23 Total EMP revalue impulse counter 23 Total operating h...

Page 32: ...de Technical Stand 09 2019 We reserve the right to technical changes in the production and technical developments For technical information during our business hours Monday Thursday 8 00 a m 16 00 p m and Friday 8 00 a m 13 00 p m choose 49 541 97120 0 or visit our homepage www holtkamp de ...

Reviews: